Errata: “Off-Design Modeling and Operational Optimization of Trans-Critical Carbon Dioxide Heat Pumps” [ASME J. Eng. Gas Turbines Power, 2022, 144(10), p. 101004]

نویسندگان

چکیده

Abstract We note that Eq. (7) in the original paper is wrong, namely, it contains turbomachinery diameter, D, at denominator instead of numerator

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Investigation of Two Two-Stage Trans-Critical Carbon Dioxide Refrigeration Cycles Ejector and Internal Heat Exchanger

In the present work, the performances of improved two-stage multi inter-cooler trans- critical carbon dioxide (CO2) refrigeration cycles with ejector and internal heat exchanger have been examined. In the new improved cycles, an internal heat exchanger is append to the cycles. Also, second inter-cooler in improved cycles, cooled with the refrigeration of the cycle, so that in first c...

متن کامل

Multidiscipinary Optimization For Gas Turbines Design

State-of-the-art aeronautic Low Pressure gas Turbines (LPTs) are already characterized by high quality standards, thus they offer very narrow margins of improvement. Typical design process starts with a Concept Design (CD) phase, defined using mean-line 1D and other loworder tools, and evolves through a Preliminary Design (PD) phase, which allows the geometric definition in details. In this fra...

متن کامل

Economic optimization and comparative study of solar heat pumps

In this paper, an economic study of solar heat pumps and an investigation of differences between solar heat pumps and conventional heat pumps—based on their performances and energy consumption—are conducted for a residential apartment located in Austin, Texas, USA. Heating in the apartment is provided via a solar heat pump during the cold months of a year. Solar collectors are used to meet the ...

متن کامل

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Models for unitary air conditioners and heat pumps typically have difficulties in providing accurate predictions for the following situations: 1) charge modeling over a large range of charge levels, 2) two-phase refrigerant entering fixed-orifice expansion devices, 3) two-phase refrigerant entering compressors, and 4) non-uniform refrigerant mass flow allocation among evaporator circuits at low...

متن کامل

Experimental Investigation and Modeling of Carbon Dioxide Adsorption from Model Flue gas

In this work, the adsorption of carbon dioxide from model flue gas on different adsorbents has been investigated. Using simplified modeling, parameters such as the total mass transfer coefficient and the effective diffusivity have been determined. Experiments were carried out in two sections: firstly, adsorption of pure carbon dioxide on different adsorbents was measured at pressures ranging fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of engineering for gas turbines and power

سال: 2023

ISSN: ['0742-4795', '1528-8919']