Equivalence of Gyn GEC-ESTRO guidelines for image guided cervical brachytherapy with EUD-based dose prescription

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Equivalence of Gyn GEC-ESTRO guidelines for image guided cervical brachytherapy with EUD-based dose prescription

BACKGROUND To establish a generalized equivalent uniform dose (gEUD) -based prescription method for Image Guided Brachytherapy (IGBT) that reproduces the Gyn GEC-ESTRO WG (GGE) prescription for cervix carcinoma patients on CT images with limited soft tissue resolution. METHODS The equivalence of two IGBT planning approaches was investigated in 20 patients who received external beam radiothera...

متن کامل

AAPM and GEC-ESTRO guidelines for image-guided robotic brachytherapy: report of Task Group 192.

In the last decade, there have been significant developments into integration of robots and automation tools with brachytherapy delivery systems. These systems aim to improve the current paradigm by executing higher precision and accuracy in seed placement, improving calculation of optimal seed locations, minimizing surgical trauma, and reducing radiation exposure to medical staff. Most of the ...

متن کامل

Prescription dose evaluation for APBI with noninvasive image-guided breast brachytherapy using equivalent uniform dose.

PURPOSE Noninvasive image-guided breast brachytherapy (NIBB) is an attractive novel approach to deliver accelerated partial breast irradiation (APBI). Calculations of equivalent uniform dose (EUD) were performed to identify the appropriate APBI dose for this technique. METHODS AND MATERIALS APBI plans were developed for 15 patients: five with three-dimensional conformal APBI (3D-CRT), five wi...

متن کامل

Recommendations from gynaecological (GYN) GEC ESTRO working group (II): concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy-3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology.

The second part of the GYN GEC ESTRO working group recommendations is focused on 3D dose-volume parameters for brachytherapy of cervical carcinoma. Methods and parameters have been developed and validated from dosimetric, imaging and clinical experience from different institutions (University of Vienna, IGR Paris, University of Leuven). Cumulative dose volume histograms (DVH) are recommended fo...

متن کامل

GEC-ESTRO recommendations for brachytherapy for head and neck squamous cell carcinomas.

Both primary and recurrent squamous cell carcinoma of the head and neck are classic indications for brachytherapy. A high rate of local tumor control at the cost of limited morbidity can be achieved with brachytherapy through good patient selection, meticulous source implantation and careful treatment planning. However, no randomized trials have been performed, and there is scant evidence in th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiation Oncology

سال: 2013

ISSN: 1748-717X

DOI: 10.1186/1748-717x-8-266