EPR Oxygen Images Predict Tumor Control by a 50% Tumor Control Radiation Dose

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Studies EPR Oxygen Images Predict Tumor Control by a 50% Tumor Control Radiation Dose

Clinical trials to ameliorate hypoxia as a strategy to relieve the radiation resistance it causes have prompted a need to assay the precise extent and location of hypoxia in tumors. Electron paramagnetic resonance oxygen imaging (EPR O2 imaging) provides a noninvasive means to address this need. To obtain a preclinical proof-ofprinciple that EPR O2 images could predict radiation control, we tre...

متن کامل

EPR oxygen images predict tumor control by a 50% tumor control radiation dose.

Clinical trials to ameliorate hypoxia as a strategy to relieve the radiation resistance it causes have prompted a need to assay the precise extent and location of hypoxia in tumors. Electron paramagnetic resonance oxygen imaging (EPR O2 imaging) provides a noninvasive means to address this need. To obtain a preclinical proof-of-principle that EPR O2 images could predict radiation control, we tr...

متن کامل

predict tumor control by a 50 percent tumor control radiation dose

Martyna Elas , Jessica M. Magwood , Brandi Butler , Chanel Li , Rona Wardak, Eugene D. Barth , Boris Epel , Samuel Rubinstein , Charles A. Pelizzari, Ralph R. Weichselbaum 1 and Howard J. Halpern Departments of: Radiation and Cellular Oncology and Radiology, University of Chicago Pritzker School of Medicine, Chicago, IL; Center for Electron Paramagnetic Resonance Imaging In Vivo Physiology, Uni...

متن کامل

Reinforcement learning based feedback control of tumor growth by limiting maximum chemo-drug dose using fuzzy logic

In this paper, a model-free reinforcement learning-based controller is designed to extract a treatment protocol because the design of a model-based controller is complex due to the highly nonlinear dynamics of cancer. The Q-learning algorithm is used to develop an optimal controller for cancer chemotherapy drug dosing. In the Q-learning algorithm, each entry of the Q-table is updated using data...

متن کامل

Automatic detection of liver tumor motion by fluoroscopy images

Background: A method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. Materials and Methods: The method was based on the following idea: (i) Before treatment, a series of fluoroscopic images corresponding to different bre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Cancer Research

سال: 2013

ISSN: 0008-5472,1538-7445

DOI: 10.1158/0008-5472.can-13-0069