EP-2086: Synthetic CT generation from standard T2-weighted MR image – lung, vertebrae, and liver targets
نویسندگان
چکیده
منابع مشابه
T2-weighted Liver Mri at 3t Using a Blade Technique: Comparison with a Standard Rectilinear T2-weighted Sequence for Image Quality and Lesion Detection
Introduction: The quality of T2-weighted images (T2WI) of the liver in the clinical setting is often degraded by ghosting artifact from various sources of motion. This artifact can obscure the margins of the liver, intra-hepatic vessels, and focal liver lesions, lowering diagnostic utility. One study has noted that such motion within the liver is more severe at 3T compared with at 1.5T [1]. Fur...
متن کاملDeep Embedding Convolutional Neural Network for Synthesizing CT Image from T1-Weighted MR Image
Recently, more and more attention is drawn to the field of medical image synthesis across modalities. Among them, the synthesis of computed tomography (CT) image from T1-weighted magnetic resonance (MR) image is of great importance, although the mapping between them is highly complex due to large gaps of appearances of the two modalities. In this work, we aim to tackle this MR-to-CT synthesis b...
متن کاملT2*-weighted image/T2-weighted image fusion in postimplant dosimetry of prostate brachytherapy.
Computed tomography (CT)/magnetic resonance imaging (MRI) fusion is considered to be the best method for postimplant dosimetry of permanent prostate brachytherapy; however, it is inconvenient and costly. In T2*-weighted image (T2*-WI), seeds can be easily detected without the use of an intravenous contrast material. We present a novel method for postimplant dosimetry using T2*-WI/T2-weighted im...
متن کاملcomparison of mr images for age determination; t1 weighted images (t1wi) versus t2* weighted images (t2*wi)
purpose t1wi (t1 weighted image) was acquired in order to grade bone fusion following the studies by fifa (federation internationale de football associations). research using images other than t1wi has not been reported. the aim of this study is to evaluate the grade of epiphyseal fusion by t2* weighted images (t2*wi) and to investigate new findings on t2*wi as compared with t1wi. methods a tot...
متن کاملComparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2018
ISSN: 0167-8140
DOI: 10.1016/s0167-8140(18)32395-8