EP-2081 Real time CyberKnife dosimetry using Radioluminescence imaging
نویسندگان
چکیده
منابع مشابه
Real-time Cherenkov emission portal imaging during CyberKnife® radiotherapy.
The feasibility of real-time portal imaging during radiation therapy, through the Cherenkov emission (CE) effect is investigated via a medical linear accelerator (CyberKnife(®)) irradiating a partially-filled water tank with a 60 mm circular beam. A graticule of lead/plywood and a number of tissue equivalent materials were alternatively placed at the beam entrance face while the induced CE at t...
متن کاملRadioluminescence of red-emitting Eu-doped phosphors for fiberoptic dosimetry.
Fiberoptic dosimetry (FOD) technique has become an attractive method for real-time dosimetry. Al(2)O(3):Cis one of the most used radioluminescence materials for FOD due to its high efficiency but it presents the drawback of emitting in the spectral region, where spurious luminescence is also important. Optical filtering is the simplest technique to remove spurious luminescence, but is useful wh...
متن کاملReal-Time Dosimetry for Prostate Brachytherapy Using TRUS and Fluoroscopy
A means of achieving real-time dosimetry for prostate brachytherapy using transrectal ultrasound (TRUS) and fluoroscopy has been developed. The approach is designed to fit into the current protocol used at the Vancouver Cancer Center (VCC) for prostate brachytherapy. The TRUS and fluoroscopic images are fused using a single fluoroscopic image of the TRUS probe. The tip of each needle, used to i...
متن کاملSimulation of a Neutron Detector for Real Time Imaging Applications
Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...
متن کاملDev126235 2081..2081
Developmental processes such as morphogenesis, patterning and differentiation are continuously active in the adult Hydra polyp. We carried out a small molecule screen to identify compounds that affect patterning in Hydra. We identified a novel molecule, DAC-2-25, that causes a homeotic transformation of body column into tentacle zone. This transformation occurs in a progressive and polar fashio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2019
ISSN: 0167-8140
DOI: 10.1016/s0167-8140(19)32501-0