EP-1996: Post IVD verification and recalibration of MOSkins using a certified low dose emitting Sr-90 source

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Dose Calculation of 90 Sr/ 90 Y Source in Water Phantom

Introduction:  90 Sr/ 90 Y source  has  been  used  for  the  intravascular  brachytherapy  to  prevent  coronary  restenosis in the patients who have undergone angioplasty. The aim of this research is to determine the  dose distribution of  90 Sr/ 90 Y source in a water phantom.  Materials  and  Methods:  In  the  present  work,  MCNP  code  has  been  applied  to  calculate  the  dose  distri...

متن کامل

monte carlo dose calculation of 90 sr/ 90 y source in water phantom

introduction:  90 sr/ 90 y source  has  been  used  for  the  intravascular  brachytherapy  to  prevent  coronary  restenosis in the patients who have undergone angioplasty. the aim of this research is to determine the  dose distribution of  90 sr/ 90 y source in a water phantom.  materials  and  methods:  in  the  present  work,  mcnp  code  has  been  applied  to  calculate  the  dose  distri...

متن کامل

automatic verification of authentication protocols using genetic programming

implicit and unobserved errors and vulnerabilities issues usually arise in cryptographic protocols and especially in authentication protocols. this may enable an attacker to make serious damages to the desired system, such as having the access to or changing secret documents, interfering in bank transactions, having access to users’ accounts, or may be having the control all over the syste...

15 صفحه اول

In vivo dose verification using using an amorphous silicon flat panel-type imager (a-Si EPIDs)

Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient usin...

متن کامل

a comparative move analysis of the introduction sections of ma theses by iranian and native post-graduate students

since esp received universal attention to smooth the path for academic studies and productions, a great deal of research and studies have been directed towards this area. swales’ (1990) model of ra introduction move analysis has served a pioneering role of guiding many relevant studies and has proven to be productive in terms of helpful guidelines that are the outcome of voluminous productions ...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiotherapy and Oncology

سال: 2016

ISSN: 0167-8140

DOI: 10.1016/s0167-8140(16)33247-9