EP-1991: The dosimetric characteristics of GMS BT-125-1 I-125 radioactive seed

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric characterization of GMS BT‐125‐1 125I radioactive seed with Monte Carlo simulations and experimental measurement

PURPOSE To investigate the dosimetric characteristics of the new GMS BT-125-1 125 I radioactive seed, including dose rate constant, radial dose functions, and anisotropy functions. METHODS Dosimetric parameters of GMS BT-125-1 125 I seed including dose rate constant, radial dose functions, and anisotropy functions were calculated using the Monte Carlo code of MCNP5, and measured with thermolu...

متن کامل

Dosimetric Parameters Estimation of I-125 Brachytherapy Source in fat phantom using GATE8.0 code

Introduction: Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated, are placed as close as possible to the tumor site or inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule to create optimal treatment plant. In this way, dosimetric parameters are...

متن کامل

Estimation of dosimetric parameters of I-125 brachytherapy source model 6711 using GATE8.1 code

Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...

متن کامل

Stenting of the Portal Vein Combined with Different Numbers of Iodine-125 Seed Strands: Dosimetric Analyses

Background: Portal-vein stent combined with one iodine-125 (125I) seed strand has become a new treatment for portal vein tumor thrombosis. However, dosimetric aspects of this irradiation stent have not been reported. Therefore, we aimed to undertake dosimetric analyses comparing portal-vein stents combined with different numbers of 125I seed strands. Methods: A water cylinder was created by a...

متن کامل

Previous Volumes 1 - 125

Volume 125 Published by Foundation of Computer Science (FCS), NY, USA Indexed with Google Scholar, CiteSeer and CSA Technology Research Database, ProQuest Volume 124 Published by Foundation of Computer Science (FCS), NY, USA Indexed with Google Scholar, CiteSeer and CSA Technology Research Database, ProQuest Volume 123 Published by Foundation of Computer Science (FCS), NY, USA Indexed with Go...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiotherapy and Oncology

سال: 2016

ISSN: 0167-8140

DOI: 10.1016/s0167-8140(16)33242-x