EP-1822: Surface dose variations by protective dressings during radiotherapy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of skin dose variations produced by a silicon-based protective dressing in radiotherapy.

Variations in skin dose caused by a silicon-based burn dressing used in radiotherapy during treatment have been investigated. Measurement of these variations in skin dose has been achieved using thermoluminescent dosimeters (TLDs) and Gafchromic film. For a 6 MV x-ray beam results have shown that an approximately 0.4 mm thick silicon mesh dressing increases the average surface dose by approxima...

متن کامل

Wound Dressings During Radiotherapy for Cancer: A Survey of Practice.

BACKGROUND Patients undergoing radiotherapy may experience changes to the skin that require dressings. Recommendations regarding radiating through wound dressings have been variable and relate to the concern regarding surface dose increase or bolus effect. OBJECTIVES The purpose of this article is to identify current evidence and practice through literature review and a national environmental...

متن کامل

Review of surface dose detectors in radiotherapy

Several instruments have been used to measure absorbed radiation dose under non-electronic equilibrium conditions, such as in the build-up region or near the interface between two different media, including the surface." Many of these detectors are discussed in this paper. A common method of measuring the absorbed dose distribution and electron contamination in the build-up region of high-energ...

متن کامل

Dose optimisation during imaging in radiotherapy

The desire to increase the precision in radiotherapy delivery has led to the development of advanced imaging systems such as amorphous silicon (a-Si)-based electronic portal imaging, and kV and MV cone beam CT. These are used prior to the delivery of radiation to visualise the organ to be treated and to ensure that the patient setup and treatment delivery are accurate. However, little attention...

متن کامل

On the Use of Optically Stimulated Luminescent Dosimeter for Surface Dose Measurement during Radiotherapy

This study was carried out to investigate the suitability of using the optically stimulated luminescence dosimeter (OSLD) in measuring surface dose during radiotherapy. The water equivalent depth (WED) of the OSLD was first determined by comparing the surface dose measured using the OSLD with the percentage depth dose at the buildup region measured using a Markus ionization chamber. Surface dos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiotherapy and Oncology

سال: 2018

ISSN: 0167-8140

DOI: 10.1016/s0167-8140(18)32131-5