EP-1763 Monitoring total skin electron therapy using optically stimulated luminescence dosimeters
نویسندگان
چکیده
منابع مشابه
Fiber Optic remote gamma dosimeters based on Optically Stimulated Luminescence: State-of-the-art at CEA
Optically Stimulated Luminescence (OSL) used in conjunction with optical fibres allows remote measurements of both dose and dose rate for the purpose of radiation protection in nuclear industry and medecine (radiology, radiotherapy), monitoring of installations (dismantling) as well as in process controls. Since 1995, two types of OSL systems have been developed by the Optical Measurement Labor...
متن کاملTotal skin electron therapy (TSET): Monte Carlo Simulation and implementation
Introduction: Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Operating procedures for total skin electron irradiation and its dosimetry vary in different radiation therapy centers in the world. In this article, validation of TSET techniq...
متن کاملOptically stimulated luminescence in synthetic quartz
Optically stiniulated luminescence (OSL). has been studied in synthetic quartz crystals. which had previously been exposed to Jtor X-irradiations. The main emission hands appeared at 380 and -~440 nm. The excitation spectra of these emission bands were now measured and showed both a maximum at 330nm. This maximum coincides with an excitation maximum of the phototransferred thermoluminescence (P...
متن کاملOptically Stimulated Luminescence Dating (Instrument Design for Mars Applications)
Introduction: To examine the geological and climatic history on Mars, we investigate an instrument design for robotic, in-situ, Optically Stimulated Luminescence dating (OSL). In this paper, we discuss the basic concepts of OSL, its benefits, and how this technique can be utilized on Mars. Also presented are the vital electronics needed for an instrument design and some of their basic operation...
متن کاملMeasuring patient’s skin dose during total skin electron therapy using MOSFET
It is vital to measure the dose to the patient's skin during the treatment of total skin electron therapy (TSET). Purpose of the present study is to determine the benefits of using One-Dose MOSFET detectors in the treatment of mycosis fungiodes with TSET protocol. During the study six patients with advanced stage of (MF) were treated by (TSET) using a six dual-field Stanford technique. One-Dose...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2019
ISSN: 0167-8140
DOI: 10.1016/s0167-8140(19)32183-8