EP-1754 High-resolution assessment of dose calculations in small MV photon beams on and off central axis
نویسندگان
چکیده
منابع مشابه
Dose Calculations for Lung Inhomogeneity in High-Energy Photon Beams and Small Beamlets: A Comparison between XiO and TiGRT Treatment Planning Systems and MCNPX Monte Carlo Code
Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...
متن کاملmeasurement of neutron dose component in central axis absorbed dose of 18 mv photon beam by tld600 and tld700 dosimeters
background : in spite of clinically useful photon and electron beams, high energy linacs produce secondary particles such as neutrons (photo-neutron production). neutrons have important roles during treatment with high energy photons in terms of protection and dose escalation. in this project, neutron dose equivalent of 18 mv varian accelerators is calculated by tld600 and tld700. materials and...
متن کاملAssessment of skyshine photon dose rates from 9 and 18 MV medical linear accelerators
Background: Skyshine describes the radiation scattered by the atmosphere above a LINAC facility to a point on the ground. The aim of this study was to measure the skyshine photon dose rates from two different (9 MV and 18 MV) medical linear accelerators. Materials and Methods: The photon beam was directed upward (180° gantry position), with a maximum photon field size (40 × 40 cm2) at the isoce...
متن کاملdose calculations for lung inhomogeneity in high-energy photon beams and small beamlets: a comparison between xio and tigrt treatment planning systems and mcnpx monte carlo code
introduction radiotherapy with small fields is used widely in newly developed techniques. additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. in the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against monte carlo method. materials and methods siemens once or linea...
متن کاملSurface dose variations in 6 and 10 MV flattened and flattening filter‐free (FFF) photon beams
As the use of linear accelerators operating in flattening filter-free (FFF) modes becomes more widespread, it is important to have an understanding of the surface doses delivered to patients with these beams. Flattening filter removal alters the beam quality and relative contributions of low-energy X-rays and contamination electrons in the beam. Having dosimetric data to describe the surface do...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2019
ISSN: 0167-8140
DOI: 10.1016/s0167-8140(19)32174-7