EP-1731 Using plane-parallel ionization chamber PPC40 to measure Dose Area Product Ratio

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Commissioning of a PTW 34070 large‐area plane‐parallel ionization chamber for small field megavoltage photon dosimetry

PURPOSE This study investigates a large-area plane-parallel ionization chamber (LAC) for measurements of dose-area product in water (DAPw ) in megavoltage (MV) photon fields. METHODS Uniformity of electrode separation of the LAC (PTW34070 Bragg Peak Chamber, sensitive volume diameter: 8.16 cm) was measured using high-resolution microCT. Signal dependence on angle α of beam incidence for squar...

متن کامل

Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy

Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...

متن کامل

Dosimetric characterization of a large area pixel-segmented ionization chamber.

A pixel-segmented ionization chamber has been designed and built by Torino University and INFN. The detector features a 24 x 24 cm2 active area divided in 1024 independent cylindrical ionization chambers and can be read out in 500 micros without introducing dead time; the digital charge quantum can be adjusted between 100 fC and 800 fC. The sensitive volume of each single ionization chamber is ...

متن کامل

Application of Dose-Area Product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology

Background: Application of Dose-area product (DAP) quantity has been increased in the clinical practice. DAP is relatively easy to measure. DAP has been shown to correlate well with the total energy imparted to the patient, which is related to the effective dose. Material and Methods: In this study, measurements of DAP were carried out in a sample of 421 adult patients who underwent convention...

متن کامل

Perturbation correction factors for the NACP-02 plane-parallel ionization chamber in water in high-energy electron beams.

Recent dosimetry protocols for clinical high-energy electron beams recommend measurements of absorbed dose-to-water with a plane-parallel or cylindrical ionization chamber. For well-guarded plane-parallel ionization chambers, the ionization chamber perturbation factor in water, p(Q), has a recommended value of unity in all protocols. This assumption was investigated in detail in this study for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiotherapy and Oncology

سال: 2019

ISSN: 0167-8140

DOI: 10.1016/s0167-8140(19)32151-6