EP-1519: Automatic detection of MLC position errors using an EPID based picket fence test

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring daily MLC positional errors using trajectory log files and EPID measurements for IMRT and VMAT deliveries.

This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was developed, and validated, to track MLC positional accuracy with the rotational and sta...

متن کامل

MLC positional accuracy evaluation through the Picket Fence test on EBT2 films and a 3D volumetric phantom

The accuracy of MLC positions during radiotherapy is important as even small positional deviations can translate into considerable dose delivery errors. This becomes crucial when radiosensitive organs are located near the treated volume and especially during IMRT, where dose gradients are steep. A test commonly conducted to measure the positional accuracy of the MLCs is the Picket Fence test. I...

متن کامل

Evaluation of the truebeam machine performance check (MPC): mechanical and collimation checks

Machine performance check (MPC) is an automated and integrated image-based tool for verification of beam and geometric performance of the TrueBeam linac. The aims of the study were to evaluate the performance of the MPC geometric tests relevant to beam collimation (MLC and jaws) and mechanical systems (gantry and collimator). Evaluation was performed by comparing MPC to QA tests performed routi...

متن کامل

Investigation of error detection capabilities of phantom, EPID and MLC log file based IMRT QA methods

A patient specific quality assurance (QA) should detect errors that originate anywhere in the treatment planning process. However, the increasing complexity of treatment plans has increased the need for improvements in the accuracy of the patient specific pretreatment verification process. This has led to the utilization of higher resolution QA methods such as the electronic portal imaging devi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiotherapy and Oncology

سال: 2016

ISSN: 0167-8140

DOI: 10.1016/s0167-8140(16)32769-4