EP-1515: A novel attachment system for cutouts in kilovoltage x-ray beam therapy
نویسندگان
چکیده
منابع مشابه
Advances in kilovoltage x-ray beam dosimetry.
This topical review provides an up-to-date overview of the theoretical and practical aspects of therapeutic kilovoltage x-ray beam dosimetry. Kilovoltage x-ray beams have the property that the maximum dose occurs very close to the surface and thus, they are predominantly used in the treatment of skin cancers but also have applications for the treatment of other cancers. In addition, kilovoltage...
متن کاملComparison of kilovoltage x-ray and electron beam dose distributions for radiotherapy of the sternum.
The dose distributions for a patient with cancer involving the sternum were calculated for both a kilovoltage x-ray beam and a megavoltage electron beam. The minimum target dose and dose uniformity over the target volume were significantly better using electrons (90%-101%) than kilovoltage x-rays (68%-119%). The calculated lung dose and integral patient dose were also less for electrons than ki...
متن کاملCommissioning kilovoltage cone‐beam CT beams in a radiation therapy treatment planning system
The feasibility of accounting of the dose from kilovoltage cone-beam CT in treatment planning has been discussed previously for a single cone-beam CT (CBCT) beam from one manufacturer. Modeling the beams and computing the dose from the full set of beams produced by a kilovoltage cone-beam CT system requires extensive beam data collection and verification, and is the purpose of this work. The be...
متن کاملAngular dependence of the output of a kilovoltage X‐ray therapy unit
During the recommissioning of a Philips RT-250 kilovoltage X-ray unit, unexpected output variations with tube head rotation (cross-plane) and tube head tilt (in-plane) were observed. The measured output showed an increase of up to 7.3% relative to the neutral position (0? in-plane and 0? cross-plane) over the possible range of angles of in-plane rotation for 75 kVp (half-value layer, HVL = 1.84...
متن کاملIntroducing a novel Polyvinyl chloride/Tungsten composites for shielding against gamma and X-ray radiations
Introduction: This study introduces a novel polyvinyl chloride (PVC)/tungsten composites with characterization of their shielding properties by employing different techniques. Methods: The PVC/tungsten composites were produced by employing various weight fractions of tungsten micro-particles including 0, 20, and 40 % wt via melt blending method. In the next st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2017
ISSN: 0167-8140
DOI: 10.1016/s0167-8140(17)31950-3