EP-1496: Small field correction factors for the IBA Razor

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Small field detector correction factors: effects of the flattening filter for Elekta and Varian linear accelerators

Flattening filter-free (FFF) beams are becoming the preferred beam type for stereotactic radiosurgery (SRS) and stereotactic ablative radiation therapy (SABR), as they enable an increase in dose rate and a decrease in treatment time. This work assesses the effects of the flattening filter on small field output factors for 6 MV beams generated by both Elekta and Varian linear accelerators, and d...

متن کامل

Estimation of Dosimetric Parameters based on KNR and KNCSF Correction Factors for Small Field Radiation Therapy at 6 and 18 MV Linac Energies using Monte Carlo Simulation Methods

Background: Estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. Hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...

متن کامل

On the Bayesian “occam Factors” Argument for Occam’s Razor

This paper discusses some of the problematic aspects of the Bayesian first-principles “proof” of Occam’s razor which involves Occam factors. Although it is true that the posterior for a model is reduced due to Occam factors if that model is capable of expressing many functions, the phenomenon need not have anything to do with Occam’s razor. This paper shows this by i) performing reductio ad abs...

متن کامل

Npgrj_nn_1552 1494..1496

With practice, we become increasingly efficient at visual object comparisons. This may be due to the formation of a memory template that not only binds individual features together to create an object, but also links the object with an associated response. In a longitudinal fMRI study of object matching, evidence for this link between perception and action was observed as a shift of activation ...

متن کامل

Energy and field size dependence of a silicon diode designed for small-field dosimetry

Purpose: To investigate the energy dependence/spectral sensitivity of silicon diodes designed for small-field dosimetry and obtain response factors (RFs) for arbitrary photon spectra using Monte Carlo (MC) simulations.   Methods: The EGSnrc user-code DOSRZnrc was used to calculate the dose deposition in water and in the active volume of a stereotactic diode f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiotherapy and Oncology

سال: 2016

ISSN: 0167-8140

DOI: 10.1016/s0167-8140(16)32746-3