EP-1285: Clinical results of image-guided liver SBRT using VMAT and real-time adaptive tumor gating
نویسندگان
چکیده
منابع مشابه
Clinical results of mean GTV dose optimized robotic guided SBRT for liver metastases
BACKGROUND We retrospectively evaluated the efficacy and toxicity of gross tumor volume (GTV) mean-dose-optimized and real-time motion-compensated robotic stereotactic body radiation therapy (SBRT) in the treatment of liver metastases. METHODS Between March 2011 and July 2015, 52 patients were treated with SBRT for a total of 91 liver metastases (one to four metastases per patient) with a med...
متن کاملTreatment precision of image-guided liver SBRT using implanted fiducial markers depends on marker-tumour distance.
The purpose of this study is to assess the accuracy of day-to-day predictions of liver tumour position using implanted gold markers as surrogates and to compare the method with alternative set-up strategies, i.e. no correction, vertebrae and 3D diaphragm-based set-up. Twenty patients undergoing stereotactic body radiation therapy (SBRT) with abdominal compression for primary or metastatic liver...
متن کاملReal-time damage detection of bridges using adaptive time-frequency analysis and ANN
Although traditional signal-based structural health monitoring algorithms have been successfully employed for small structures, their application for large and complex bridges has been challenging due to non-stationary signal characteristics with a high level of noise. In this paper, a promising damage detection algorithm is proposed by incorporation of adaptive signal processing and Artificial...
متن کاملReal-Time Image Guided Neurosurgery Using Distributed and Grid Computing
Neurosurgical resection is a therapeutic intervention in the treatment of brain tumors. Precision of the resection can be improved by utilizing Magnetic Resonance Imaging (MRI) as an aid in decision making during Image Guided Neurosurgery (IGNS). Image registration adjusts pre-operative data according to intra-operative tissue deformation. Some of the approaches increase the registration accura...
متن کاملViability of Noncoplanar VMAT for liver SBRT compared with coplanar VMAT and beam orientation optimized 4π IMRT
PURPOSE The 4π static non-coplanar radiotherapy delivery technique has demonstrated better normal tissue sparing and dose conformity than the clinically used volumetric modulated arc therapy (VMAT). It is unclear whether this is a fundamental limitation of VMAT delivery or the coplanar nature of its typical clinical plans. The dosimetry and the limits of normal tissue toxicity constrained dose ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2015
ISSN: 0167-8140