EP-1255: Early clinical results for esophageal brachytherapy using a novel multi-balloon HDR applicator
نویسندگان
چکیده
منابع مشابه
Intracavitary vaginal brachytherapy using a custom balloon applicator
A custom balloon applicator was created to deliver intracavitary high-dose-rate brachytherapy to a patient with a superficial vaginal cancer. The patient was unable to be treated conventionally due to an extremely narrow introitus that prevented the introduction of a conventional cylinder applicator. The custom applicator was constructed by inserting a straight titanium tandem applicator throug...
متن کاملClinical implementation of a novel applicator in high-dose-rate brachytherapy treatment of esophageal cancer
PURPOSE In this study, we present the clinical implementation of a novel transoral balloon centering esophageal applicator (BCEA) and the initial clinical experience in high-dose-rate (HDR) brachytherapy treatment of esophageal cancer, using this applicator. MATERIAL AND METHODS Acceptance testing and commissioning of the BCEA were performed prior to clinical use. Full performance testing was...
متن کاملApplicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film
Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...
متن کاملDosimetric evaluation of a novel high dose rate (HDR) intraluminal / interstitial brachytherapy applicator for gastrointestinal and bladder cancers
High dose rate (HDR) brachytherapy is one of the accepted treatment modalities in gastro-intestinal tract and bladder carcinomas. Considering the shortcoming of contact brachytherapy routinely used in gastrointestinal tract in treatment of big tumors or invasive method of bladder treatment, an intraluminal applicator with the capability of insertion into the tumor depth seems to be useful. This...
متن کاملDose optimization of breast balloon brachytherapy using a stepping Ir192 HDR source
There is a considerable underdosage (11%-13%) of PTV due to anisotropy of a stationary source in breast balloon brachytherapy. We improved the PTV coverage by varying multiple dwell positions and weights. We assumed that the diameter of spherical balloons varied from 4.0 cm to 5.0 cm, that the PTV was a 1-cm thick spherical shell over the balloon (reduced by the small portion occupied by the ca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2017
ISSN: 0167-8140
DOI: 10.1016/s0167-8140(17)31690-0