EP-1135: Evaluation of dosimetric accuracy of stereotactic radiotherapy with new radiochromic EBT3 film
نویسندگان
چکیده
منابع مشابه
Multi-dimensional dosimetric verification of stereotactic radiotherapy for uveal melanoma using radiochromic EBT film.
Since 1997, linac based stereotactic radiotherapy (SRT) of uveal melanoma has been continuously developed at the Department of Radiotherapy, Medical University Vienna. The aim of the present study was (i) to test a new type of radiochromic film (Gafchromic EBT) for dosimetric verification of class solutions for these treatments and (ii) to verify treatment plan acceptance criteria, which are ba...
متن کاملComparison of EBT and EBT3 RadioChromic Film Usage in Parotid Cancer Radiotherapy
Background: EBT and EBT3 radioChromic films have been used in radiotherapy dosimetry for years.Objective: The aim of the current study is to compare EBT and EBT3 radioChromic films in dosimetry of radiotherapy fields for treatment of parotid cancer.Methods: Calibrations of EBT and EBT3 films were performed with identical setups using a 6 MV photon beam of a Siemens Primus linac. Skin dose was m...
متن کاملComparison of EBT and EBT3 RadioChromic Film Usage in Parotid Cancer Radiotherapy
BACKGROUND EBT and EBT3 radioChromic films have been used in radiotherapy dosimetry for years. OBJECTIVE The aim of the current study is to compare EBT and EBT3 radioChromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. METHODS Calibrations of EBT and EBT3 films were performed with identical setups using a 6 MV photon beam of a Siemens Primus linac. Skin dose wa...
متن کاملPrecise film dosimetry for stereotactic radiosurgery and stereotactic body radiotherapy quality assurance using Gafchromic™ EBT3 films
PURPOSE The purpose of this study is to evaluate the dosimetric uncertainty associated with Gafchromic™ (EBT3) films and establish a practical and efficient film dosimetry protocol for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT). METHOD AND MATERIALS EBT3 films were irradiated at each of seven different dose levels between 1 and 15 Gy with open fields and standar...
متن کاملcomparison of ebt and ebt3 radiochromic film usage in parotid cancer radiotherapy
background: ebt and ebt3 radiochromic films have been used in radiotherapy dosimetry for years. objective: the aim of the current study is to compare ebt and ebt3 radiochromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. methods: calibrations of ebt and ebt3 films were performed with identical setups using a 6 mv photon beam of a siemens primus linac. skin dose was...