Total reflection X-ray fluorescence (TXRF) analysis is an established technique for trace-element analysis in various types of samples. Though expensive large-scale systems restricted the applications in the past, in this study the capability of a benchtop system for trace elemental analysis is reported. The suitability of this system for the mobile on-site analysis of heavy metal contaminated ...
متن کاملTrace Element Analysis Using a Benchtop Txrf-spectrometer
Total Reflection X-Ray Fluorescence Analysis (TXRF) is an established technique for trace element analysis in various sample types. Restricted in the past to expensive large-scale systems, in this study the capability of a benchtop system for trace element analysis is reported. By analysing various heavy metals in raw and digested sewage as well as mercury in recycling glass, the suitability of...
متن کاملMulti-element analysis by portable total reflection X-ray fluorescence spectrometer.
Multi-element solutions containing the 11 elements S, K, Sc, V, Mn, Co, Cu, Ga, As, Br and Y were analyzed by a portable total reflection X-ray fluorescence (TXRF) spectrometer. The excitation parameters (glancing angle, operational voltage and current) and sample amount were optimized for the portable TXRF in order to realize the smallest possible detection limits for all elements. The excitat...
متن کاملIntelligent Simultaneous Quantitative Online Analysis of Environmental Trace Heavy Metals with Total-Reflection X-Ray Fluorescence
Total-reflection X-ray fluorescence (TXRF) has achieved remarkable success with the advantages of simultaneous multi-element analysis capability, decreased background noise, no matrix effects, wide dynamic range, ease of operation, and potential of trace analysis. Simultaneous quantitative online analysis of trace heavy metals is urgently required by dynamic environmental monitoring and managem...
متن کاملTrace elemental analysis of commercial bottled drinking water by a portable total reflection X-ray fluorescence spectrometer.
A portable total reflection X-ray fluorescence spectrometer was applied to commercial bottled drinking water containing 62 ppb (microg/L) V, 7.5 ppm (mg/L) Ca, and 1 ppm K. A dry residue, prepared by repeated pipetting and drying a 20 microL portion of drinking water on a sample holder six times, and another dry residue, prepared by pipetting and drying a 120 microL portion of the drinking wate...