Entrapment of Guide Wire – A Preventable Complication of Balloon Mitral Valvotomy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

"percutaneous balloon mitral valvotomy with the guide of transesophageal echocardiography during pregnancy"

rheumatic mitral valve stenosis is the most common form of organic heart disease encountered during pregnancy and continues to cause maternal and fetal mortality. medically refractory congestive heart failure due to mitral stenosis is a clinical challenge and its optimal management remains controversial. on the other hand due to hazard of x-ray to mother and fetus, there are some limitations fo...

متن کامل

loss of guide wire: a rare complication of intra-aortic balloon pump insertion

at the final stages of a coronary artery bypass graft operation on a 64-year-old man, an experienced physician attempted to insert an intra-aortic balloon pump into the femoral artery via the seldinger technique. however, while the balloon pump was being passed over the guide wire, the latter was completely lost. the guide wire should be held at the tip at all times to prevent passage into the ...

متن کامل

Mitral balloon valvotomy and left atrial thrombus.

T he presence of thrombus in the left atrium (LA) is an important factor in the selection of cases for percutaneous mitral balloon valvotomy (MBV). This is because of the danger of embolisation caused by manipulation of guidewires and balloon catheters. The American College of Cardiology/American Heart Association recommendations for MBV emphasise absence of LA thrombus. Transoesophageal echoca...

متن کامل

extra luminal entrapment of guide wire; a rare complication of central venous catheter placement in right internal jugular vein

central venous catheterization (cvc) is a commonly performed procedure for venous access. it is associated with several complications. we report a rare case of extra luminal entrapment of guide wire during cvc placement in right jugular vein. we report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during cvc. x-ray sh...

متن کامل

Loss of Guide Wire: A Rare Complication of Intra-Aortic Balloon Pump Insertion

At the final stages of a coronary artery bypass graft operation on a 64-year-old man, an experienced physician attempted to insert an intra-aortic balloon pump into the femoral artery via the Seldinger technique. However, while the balloon pump was being passed over the guide wire, the latter was completely lost. The guide wire should be held at the tip at all times to prevent passage into the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical & Experimental Cardiology

سال: 2011

ISSN: 2155-9880

DOI: 10.4172/2155-9880.1000120