OBJECTIVE To report that screw-in type pacing leads can be removed by screw retraction even after a significant anchoring period. PATIENT A 78-year-old woman who visited our hospital for skin erosion over a pacemaker that had been implanted 3 years previously and had migrated from the subclavicular area to the axilla. METHODS Culture revealed a local staphylococcus infection. We placed a ne...

متن کامل

Examination of steroid release from screw-in pacing leads.

Although constant progress in pacing lead design and life time of pacemaker battery has contributed to the clinical success of this treatment option, the mechanism of drug release from steroid-eluting pacing leads is not completely understood. Besides, drug concentrations of steroids released into the heart-tissue remain unclear. Therefore, three different dissolution test methods were examined...

متن کامل

Fistula Formation 6 Years after Removal of Infected Pacemaker Leads

We describe a case of a male patient who presented with a chronic ulcer below the left clavicle. Six years before the present admission a permanent pacemaker, including leads, was explanted related to endocarditis. The initial working hypothesis suspected an infected sebaceous gland as the cause of ulceration. After two periods of unsuccessful surgical treatment of the gland, further examinatio...

متن کامل

Screw loosening and Migration after Dynesys Implantation

Due to the problems associated with rigid fixation, the concept of dynamic stabilization was introduced. Dynesys is one of the pedicle screw-based dynamic stabilization systems. In spite of the dynamic nature of Dynesys, there are concerns about the rigidity of the Dynesys system. We present a case of vertebral body split fracture after Dynesys implantation in a 74-year-old woman. She had under...

متن کامل

A Screw in the Left Bronchus Aspirated Foreign Body Diagnosed after 4 years: A Case Report

Foreign body aspiration may cause airway obstruction, either partial or total, which can be life-threatening. Delayed diagnosis will increase patient morbidity, especially the occurrence of bacterial infections. This case report discusses chronic foreign body aspiration in a six year<span...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Rural Medicine

سال: 2011

ISSN: 1880-4888,1880-487X

DOI: 10.2185/jrm.6.35