Enterococcus casseliflavus endophthalmitis due to metallic intraocular foreign body
نویسندگان
چکیده
منابع مشابه
Intravitreal moxifloxacin in the management of Ochrobactrum intermedium endophthalmitis due to metallic intraocular foreign body
A healthy 34-year-old man presented with Ochrobactrum intermedium endophthalmitis due to a metallic intraocular foreign body. After vitrectomy, lensectomy, removal of the metallic intraocular foreign body, intravitreal vancomycin and ceftazidime, and systemic ciprofloxacin, intraocular inflammation worsened. Repeat vitreous culture confirmed persistent endophthalmitis due to multidrug-resistant...
متن کاملMetallic Foreign Body in the Lung Due to Gunshot Injury
A 37 - year- old man came to the hospital with a history of penetrating thoracoabdominal trauma due to gunshot wound in 10 days before. He underwent laparatomy and hepatorrhaphy in that time and right sided chest tube was inserted. Chest CT scan revealed metallic foreign body in lung tissue due to bullet burst. Right thoracotomy was performed and metallic foreign body extracted from lung tissue
متن کاملEnterococcus casseliflavus endophthalmitis associated with a horse tail injury.
seen on color photography (Figure 2). Her visual acuity loss and fundus findings were attributed to choroidal infarction that occurred immediately postoperatively. A cerebral internal carotid artery angiogram performed 4 days postoperatively, once her proptosis resolved, revealed a surgical clip at the expected location and no evidence of a clip or obstruction at the level of the ophthalmic art...
متن کاملEnterococcus casseliflavus Endophthalmitis Associated With a Horse Tail Injury
seen on color photography (Figure 2). Her visual acuity loss and fundus findings were attributed to choroidal infarction that occurred immediately postoperatively. A cerebral internal carotid artery angiogram performed 4 days postoperatively, once her proptosis resolved, revealed a surgical clip at the expected location and no evidence of a clip or obstruction at the level of the ophthalmic art...
متن کاملmetallic foreign body in the lung due to gunshot injury
a 37 - year- old man came to the hospital with a history of penetrating thoracoabdominal trauma due to gunshot wound in 10 days before. he underwent laparatomy and hepatorrhaphy in that time and right sided chest tube was inserted. chest ct scan revealed metallic foreign body in lung tissue due to bullet burst. right thoracotomy was performed and metallic foreign body extracted from lung tissue
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Eye
سال: 2015
ISSN: 0950-222X,1476-5454
DOI: 10.1038/eye.2014.332