Enhancing multiple harmonics in tapping mode atomic force microscopy by added mass with finite size
نویسندگان
چکیده
منابع مشابه
Tapping mode atomic force microscopy in liquid
We show that standard silicon nitride cantilevers can be used for tapping mode atomic force microscopy (AFM) in air, provided that the energy of the oscillating cantilever is sufficiently high to overcome the adhesion of the water layer. The same cantilevers are successfully used for tapping mode AFhif in liquid. Acoustic modes in the liquid excite the canti1eve.r. On soft samples, e.g., biolog...
متن کاملThermally actuated tapping mode atomic force microscopy with polymer microcantilevers.
This paper demonstrates a thermally actuated tapping mode atomic force microscopy (AFM) with a polymer cantilever. The cantilever (350x250x3 microm(3)) is made from polyimide and includes an embedded resistive heater for thermal actuation. The oscillation of the cantilever is due to the stress gradient caused by alternating heating and cooling from the periodic ac excitation of the heater. The ...
متن کاملPhase imaging and stiffness in tapping-mode atomic force microscopy
The dependence of phase angles in tapping-mode atomic force microscopy on the magnitude of tip-sample repulsive interactions was investigated, and phase images of several hard and soft samples were recorded as a function of the free amplitude Ao and the set-point tapping amplitude Asp. The phase angle of probe oscillation increases with decreasing the set-point amplitude ratio Asp/Ao. Phase ima...
متن کاملSqueeze Film Air Damping in Tapping Mode Atomic Force Microscopy
In dynamic plowing lithography, the sample surface is indented using a vibrating tip in tapping mode atomic force microscopy. During writing, the gap between the cantilever and the sample surface is very small, usually on the order of micrometers. High vibration frequency and small distance induce squeeze film air damping from the air in the gap. This damping can cause variations in the cantile...
متن کاملCapillary forces in tapping mode atomic force microscopy
We investigated the influence of the relative humidity on amplitude and phase of the cantilever oscillation while operating an atomic force microscope ~AFM! in the tapping mode. If the free oscillation amplitude A0 exceeds a certain critical amplitude Ac , the amplitudeand phase-distance curves show a transition from a regime with a net attractive force between tip and sample to a net repulsive...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Physics Express
سال: 2019
ISSN: 1882-0778,1882-0786
DOI: 10.7567/1882-0786/ab5467