Enhanced seismic base isolation using inertial amplifiers

نویسندگان

چکیده

Harnessing the concept of inertial amplification, an amplifier coupled base isolator (IABI) is proposed in this paper. The seismic performance, terms story drift, shear reduction, has been compared with that classical (CBI) and inerter-based isolation system (Inerter-BI). A thorough analytical study, implementing rationals random vibration for harmonic Gaussian white noise conducted to identify performance frequency domain. Further, a numerical study determine response time-domain based base-isolated structure twenty-two real earthquake ground motions. results elucidate histogram drift reduction percentage shifts towards higher values CBI Inerter-BI. From both it observed capacity IABI significantly 89.38% 72% superior system, respectively. This finding evidenced supremacy over inerter control.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic Response Control Using Base Isolation Strategy

Earthquakes are one of the natural hazards that occur due to sudden violent movement of earth’s surface which releases energy and has destructive power in many parts of the world. The development of recent technologies for the control of seismic hazards catches the attention of structural engineers to make the structures seismically resistant. The seismic base isolation technique is a passive p...

متن کامل

Seismic Response Reduction of Structures using Smart Base Isolation System

In this study, control performance of a smart base isolation system consisting of a friction pendulum system (FPS) and a magnetorheological (MR) damper has been investigated. A fuzzy logic controller (FLC) is used to modulate the MR damper so as to minimize structural acceleration while maintaining acceptable base displacement levels. To this end, a multi-objective optimization scheme is used t...

متن کامل

Pillow-Shape Base Isolation System and Its Seismic Behavior

In this paper a new isolating system is introduced for short to mid-rise buildings. In comparison to conventional systems such as LRB and HRB, the proposed system has the advantage of no need to cutting edge technology and has low manufacturing cost. This system is made up of two orthogonal pairs of pillow-shaped rollers that are located between flat bed and plates. By using this system in two ...

متن کامل

Seismic Rehabilitation of Liquid Storage Tanks using Friction Pendulum Base Isolation subjected to the Near-Fault Ground Motions

Cylindrical liquid storage tanks are considered as vital structures in industrial complex whose nonlinear dynamic behavior is of crucial importance. Some of these structures around the world have demonstrated poor seismic behavior over the last decades. There are several methods and techniques for rehabilitation and reducing damages in these structures which among them passive control devices, ...

متن کامل

Derivation of Equation of Motion for the Pillow-Shape Seismic Base Isolation System

Rolling-based seismic isolation systems, in which rollers of circular or non-circular section are used, are less expensive and easier to manufacture. However, this type of isolation suffers from either lack of restoring or re-centering capability, or weakness against uplift forces. To resolve the first shortcoming the use of elliptical as well as pillow-shape rolling parts has been suggested, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Structures

سال: 2021

ISSN: ['2352-0124']

DOI: https://doi.org/10.1016/j.istruc.2021.04.089