Enhanced chemiluminescence (ECL) for routine immunoblotting
نویسندگان
چکیده
منابع مشابه
Electrogenerated Chemiluminescence. 62. Enhanced ECL in Bimetallic Assemblies with Ligands That Bridge Isolated Chromophores
Analytical Chemistry is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Article Electrogenerated Chemiluminescence. 62. Enhanced ECL in Bimetallic Assemblies with Ligands That Bridge Isolated Chromophores Mark M. Richter, Allen J. Bard, Won Kim, and Russel H. Schmehl Anal. Chem., 1998, 70 (2), 310-318 • DOI: 10.1021/ac970736n Downloaded from http://p...
متن کاملMetal-enhanced chemiluminescence: advanced chemiluminescence concepts for the 21st century.
Chemiluminescent-based detection is entrenched throughout the biosciences today, such as in blotting, analyte and protein quantification and detection. While the biological applications of chemiluminescence are forever growing, the underlying principles of using a probe, an oxidizer and a catalyst (biological, organic or inorganic) have remained mostly unchanged for decades. Subsequently, chemi...
متن کاملEnhanced permanganate chemiluminescence.
The significant enhancement of acidic potassium permanganate chemiluminescence by Mn(II) results from the concomitant presence of permanganate and Mn(III) in the reagent solution, which enables rapid production of the excited Mn(II) emitter with a wide range of analytes. Furthermore, the key Mn(III) co-reactant can be quickly generated by reducing permanganate with sodium thiosulfate, instead o...
متن کاملA Theoretical and Experimental Framework for Understanding Electrogenerated Chemiluminescence (ECL) Emission at Bipolar Electrodes
Bipolar electrodes are potentially useful for a variety of sensing applications, but their implementation has been hampered by an inability to easily monitor the current through such electrodes. However, current can be indirectly determined using electrogenerated chemiluminescence (ECL) as a reporting mechanism. This paper provides a detailed theoretical analysis of ECL reporting at bipolar ele...
متن کاملElectrogenerated chemiluminescence (ECL) of 2-oxa-bicyclo[3.3.0]octa-4,8-diene-3,6-dione (OBDD)
We report the electrogenerated chemiluminescence (ECL) of 2-oxa-bicyclo[3.3.0]octa-4,8-diene-3,6dione (OBDD). Cyclic voltammetry at 100 mV/s shows two chemically reversible reduction waves but an irreversible oxidation wave. As opposed to the usual radical ion annihilation ECL, for this compound, ECL was observed in an acetonitrile solution just upon oxidation to the radical cation (D) in the a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Spermatogenesis
سال: 2011
ISSN: 2156-5562
DOI: 10.4161/spmg.1.2.16606