Energy resolution improvement in room-temperature CZT detectors

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy resolution improvement in room-temperature CZT detectors

We present methods to improve the energy resolution of single channel, room-temperature Cadmium-Zinc-Telluride (CZT) detectors. A new preamplifier design enables the acquisition of the actual transient current from the crystals and straightforward data analysis methods yield unprecedented energy resolution for our test-detectors. These consist of an eVCAPture Plus crystal as standard and 1 cm c...

متن کامل

Energy Resolution Improvement of Scintielectron detectors: Priorities and Prospects

The development prospects of a scintillator-photodiode type detector with an improved energy resolution attaining few per cent, R from 1 to 2%, are considered. The main resolution components have been analyzed theoretically, their theoretical and physical limits have been established. Empirical data on the properties of novel scintillators have been presented confirming the possibility of the R...

متن کامل

CZT imaging detectors for ProtoEXIST

We describe the detector development for a balloon-borne wide-field hard X-ray (20 – 600 keV) telescope, ProtoEXIST. ProtoEXIST is a pathfinder for both technology and science of the proposed implementation of the Black Hole Finder Probe, Energetic X-ray Imaging Survey telescope (EXIST). The principal technology challenge is the development of large area, close-tiled modules of imaging CZT dete...

متن کامل

Advanced Readout ASICs for Multielement CZT Detectors

A generation of high performance front-end and read-out ASICs customized for highly segmented CdZnTe sensors is presented. The ASICs, developed in a multi-year effort at Brookhaven National Laboratory, are targeted to a wide range of applications including medical, safeguards/security, industrial, research, and spectroscopy. The front-end multichannel ASICs provide high accuracy low noise pream...

متن کامل

Silicon Drift Detectors for High Resolution, High Count Rate X-ray Spectroscopy at Room Temperature

Silicon Drift Detectors (SDDs) consist of a fully depleted volume in which an electric field drives signal charges to a small sized anode. Due to their topology SDDs combine a large sensitive area with a small output capacitance. In an advanced SDD version for X-ray spectroscopy designed and fabricated at the MPI semiconductor laboratory the input transistor of the amplifying electronics has be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Instrumentation

سال: 2007

ISSN: 1748-0221

DOI: 10.1088/1748-0221/2/12/p12003