Energy resolution improvement in room-temperature CZT detectors
نویسندگان
چکیده
منابع مشابه
Energy resolution improvement in room-temperature CZT detectors
We present methods to improve the energy resolution of single channel, room-temperature Cadmium-Zinc-Telluride (CZT) detectors. A new preamplifier design enables the acquisition of the actual transient current from the crystals and straightforward data analysis methods yield unprecedented energy resolution for our test-detectors. These consist of an eVCAPture Plus crystal as standard and 1 cm c...
متن کاملEnergy Resolution Improvement of Scintielectron detectors: Priorities and Prospects
The development prospects of a scintillator-photodiode type detector with an improved energy resolution attaining few per cent, R from 1 to 2%, are considered. The main resolution components have been analyzed theoretically, their theoretical and physical limits have been established. Empirical data on the properties of novel scintillators have been presented confirming the possibility of the R...
متن کاملCZT imaging detectors for ProtoEXIST
We describe the detector development for a balloon-borne wide-field hard X-ray (20 – 600 keV) telescope, ProtoEXIST. ProtoEXIST is a pathfinder for both technology and science of the proposed implementation of the Black Hole Finder Probe, Energetic X-ray Imaging Survey telescope (EXIST). The principal technology challenge is the development of large area, close-tiled modules of imaging CZT dete...
متن کاملAdvanced Readout ASICs for Multielement CZT Detectors
A generation of high performance front-end and read-out ASICs customized for highly segmented CdZnTe sensors is presented. The ASICs, developed in a multi-year effort at Brookhaven National Laboratory, are targeted to a wide range of applications including medical, safeguards/security, industrial, research, and spectroscopy. The front-end multichannel ASICs provide high accuracy low noise pream...
متن کاملSilicon Drift Detectors for High Resolution, High Count Rate X-ray Spectroscopy at Room Temperature
Silicon Drift Detectors (SDDs) consist of a fully depleted volume in which an electric field drives signal charges to a small sized anode. Due to their topology SDDs combine a large sensitive area with a small output capacitance. In an advanced SDD version for X-ray spectroscopy designed and fabricated at the MPI semiconductor laboratory the input transistor of the amplifying electronics has be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Instrumentation
سال: 2007
ISSN: 1748-0221
DOI: 10.1088/1748-0221/2/12/p12003