Energy Resolution Enhancement of Mercuric Iodide Detectors
نویسندگان
چکیده
منابع مشابه
Platelet growth of mercuric iodide
The Faile growth method, when used with purified mercuric iodide (HgI2), along with low molecular weight polyethylene, has yielded tetragonal prismatic HgI2 crystals. Thermal desorption-gas chromatography/mass spectroscopy (TD-GC/MS) studies reveal the existence of alkanes and ketones in the growth ampoules along with low molecular weight polyethylene, presumably decomposition byproducts from, ...
متن کاملA Manipulator Control System for Creating Radiation Maps Using Mercuric Iodide (HgI2) Detectors
In this paper we describe the development of a robotic system that uses Mercuric Iodide (HgI2) sensors to create a map of radiation intensity in the environment. The sensors are mounted at the end-effector of a PUMA 560 manipulator. Data from these sensors is used to compute the radiation intensity. A control system is developed that moves the endeffector along constant intensity contours. The ...
متن کاملA Manipulator Control System for Creating Radiation Maps Using Mercuric Iodide (Hgb) Detectors
In this paper we describe the development of a robotic system that uses Mercuric Iodide (HgI2) sensors to create a map of radiation intensity in the environment. The sensors are mounted at the end-effector of a PUMA 560 manipulator. Data from these sensors is used to compute the radiation intensity. A control system is developed that moves the endeffector along constant intensity contours. The ...
متن کاملDiscrete Scintillator Coupled Mercuric Iodide Photodetector Arrays for Breast Imaging
Multi-element (4x4) imaging arrays with high resolution collimators, size matched to discrete CsI(T1) scintillator arrays and mercuric iodide photodetector arrays (HgI, PDA) are under development as prototypes for larger 16x16 element arrays. The compact nature of the arrays allows detector positioning in proximity to the breast to eliminate activity not in the lineof-sight 0; the collimator, t...
متن کاملEnergy Resolution Improvement of Scintielectron detectors: Priorities and Prospects
The development prospects of a scintillator-photodiode type detector with an improved energy resolution attaining few per cent, R from 1 to 2%, are considered. The main resolution components have been analyzed theoretically, their theoretical and physical limits have been established. Empirical data on the properties of novel scintillators have been presented confirming the possibility of the R...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1984
ISSN: 0018-9499,1558-1578