Energy Resolution Considerations in Liquid Ionization Chambers
نویسندگان
چکیده
منابع مشابه
LET Monitoring Using Liquid Ionization Chambers
Relative biological effectiveness (RBE) is an important quantity in planning particle beam cancer therapy. In general, the RBE describes the biological effectiveness of a given primary beam with respect to a reference photon irradiation. RBE varies not only for different primary beams but also with depth in the target for a given beam modality. It is not a quantity that easily lends itself to m...
متن کاملA sampling calorimeter with warm-liquid ionization chambers
An iron sampling calorimeter with warm-liquid ionization chambers has been tested at the CERN SPS in order to study the signal development and to verify the energy calibration of the hadron calorimeter in the KASCADE-Grande air shower experiment. The absolute energy calibration of the detectors is discussed. Results of the analysis of the lateral and longitudinal shower development in the calor...
متن کاملIon recombination in liquid ionization chambers Development of an experimental method to quantify general recombination
An experimental method (the two-dose-rate method) for the correction of general recombination losses in liquid ionization chambers has been developed and employed in experiments with different liquids and radiation qualities. The method is based on a disassociation of initial and general recombination, since an ionized liquid is simultaneously affected by both of these processes. The two-dose-r...
متن کاملContamination of ionization chambers by talcum powder.
This is a word of caution to anyone using ionization chambers protected by thin rubber sheaths in water. Four Farmer-type ionization chambers contaminated with talcum powder were received for calibration by the Accredited Dosimetry Calibration Laboratory at the University of Texas M. D. Anderson Cancer Center. The chambers show a marked energy dependence (5% to 20%) to soft orthovoltage x rays....
متن کاملStandard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...