ENERGY EVALUATION OF COLD AIR DIRECT DISTRIBUTION SYSTEM
نویسندگان
چکیده
منابع مشابه
Power Distribution Development and Optimization of Hybrid Energy Storage System
In this paper, the development and optimization of Power Distribution Control Strategy (PDCS) have been performed for a Hybrid Energy Storage Systems (HESS) of a Series Hybrid Electric Bus (SHEB). A common PDCS is based on the use of Ultra-Capacitor (UC) pack. A new simple PDCS is developed as a battery based one. For the battery based PDCS, four parameters ar...
متن کاملNumerical Evaluation on a Direct-contact Thermal Energy Storage System
Weilong Wang, Shiquan He,Jing Ding, Hailong Li, Jinyue Yan, Jianping Yang School of Engineering, Sun Yat-sen University, Guangzhou, China Academy of Building Energy Efficiency of Guangzhou University, Guangzhou, China School of Business, Society and Energy, Mälardalen University, Västerås, Sweden d School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou, China
متن کاملModelling and Optimization of Direct Expansion Air Conditioning System Forcommercial Building Energy Saving
This paper presents a comprehensive refinement of system modeling and optimization study of air-cooled direct expansion (DX) refrigeration systems for commercial buildings to address the energy saving problem. An actual DX rooftop package of a commercial building in the hot and dry climate condition is used for experimentation and data collection. Both inputs and outputs are known and measured ...
متن کاملDynamic Modelling of a Compressed Air Energy Storage System in a Grid Connected Photovoltaic Plant
The use of photovoltaic (PV) cells in domestic and industrial applications has grown rapidly through the recent years. Constructing PV plants is a very smart measure to produce free electricity in large scales, especially in the countries with higher solar irradiation potential. On the other hand, compressed air energy storage (CAES) has already been proposed to be employed for energy storage a...
متن کاملEvaluation of Direct Current Distribution in Data Centers to Improve Energy Efficiency
Data centers are major power consumers. A typical new data center in the United States today has 1,000 racks, occupies 30,000 square feet, and requires 10 million watts (MW) of power to support the computing infrastructure. Projections for future data centers suggest even greater power consumption. Future 100,000-square-foot data centers could require 50 MW for the computing infrastructure and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: AIJ Journal of Technology and Design
سال: 2001
ISSN: 1341-9463,1881-8188
DOI: 10.3130/aijt.7.125_1