Endotracheal tube biofilm translocation in the lateral Trendelenburg position
نویسندگان
چکیده
منابع مشابه
Endotracheal tube biofilm translocation in the lateral Trendelenburg position
INTRODUCTION Laboratory studies demonstrated that the lateral Trendelenburg position (LTP) is superior to the semirecumbent position (SRP) in the prevention of ventilator-associated pulmonary infections. We assessed whether the LTP could also prevent pulmonary colonization and infections caused by an endotracheal tube (ETT) biofilm. METHODS Eighteen pigs were intubated with ETTs colonized by ...
متن کاملI-Gel is a suitable alternative to endotracheal tubes in the laparoscopic pneumoperitoneum and trendelenburg position
BACKGROUND The use of supraglottic airway devices (SADs) in surgeries with laparoscopic pneumoperitoneum and Trendelenburg (LPT) positioning is controversial due to concerns about insufficient pulmonary ventilation and aspiration. In this prospective, randomized-controlled trial, we evaluated whether the i-gel, a new second generation SAD, provides an effective alternative to an endotracheal tu...
متن کاملUse of ultrasonography in confirmation of endotracheal tube position
Methods This study was conducted on 100 patients who were admitted to Critical Care Medicine Department in Alexandria Main University Hospital with an indication of endotracheal tube placement. All patients were examined by ultrasonography “linear probe” after endotracheal tube insertion. Results were compared with capnometric readings (end tidal CO2). After confirmation of endotracheal tube po...
متن کاملUltrasonographic Confirmation of Endotracheal Tube Position in Neonates.
OBJECTIVE To compare endotracheal tube tip-to-carina distance obtained by ultrasonography vs. that obtained by chest X-ray in neonates. METHODS After endotracheal intubation of 40 neonates, chest X-ray and, within one hour, ultrasonography was obtained for each patient for measurement of endotracheal tube tip-to-carina distance. RESULTS Means of endotracheal tube tip-to-carina distances wer...
متن کاملEndotracheal tube extubation force: adhesive tape versus endotracheal tube holder.
BACKGROUND Adhesive tape is commonly used to secure the endotracheal tube (ETT) in anesthesia and intensive-care settings. OBJECTIVE To determine the force required to extubate when the ETT is secured with adhesive tape or commercially available ETT holders. METHODS We orally intubated a simulation manikin with a standard 8.0-mm inner-diameter ETT, inflated the cuff to 20 cm H(2)O, and mea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Critical Care
سال: 2015
ISSN: 1364-8535
DOI: 10.1186/s13054-015-0785-0