Endoscopic Killian–Jamieson diverticulotomy using a scissor-type electrosurgical knife
نویسندگان
چکیده
منابع مشابه
A Case of Corrosive Injury-Induced Pharyngeal Stricture Treated by Endoscopic Adhesiolysis Using an Electrosurgical Knife
Here, we report a case of corrosive injury-induced pharyngeal stricture in a 69-year-old female, which was successfully treated with endoscopic adhesiolysis using an electrosurgical knife. The patient had ingested sodium hydroxide in an attempted suicide, and immediate endoscopy revealed corrosive injuries of the pharynx, esophagus, and stomach. When a liquid diet was permitted, she complained ...
متن کاملEndoscopic resection of a giant pedunculated polyp using scissor-type forceps.
An 83-year-old man presented with a feeling of abdominal fullness and underwent colonoscopy. Two pedunculated polyps were identified in the sigmoid colon: the one on the oral side was about 20mm, while that on the anal side was a giant lesion nearly as large as the diameter of the bowel lumen (●" Fig.1a). It was judged to be difficult to perform polypectomy by snaring the latter polyp. Both pol...
متن کاملEndoscopic therapy of Zenker's diverticulum using a novel endoscopic scissor - the Clutch Cutter device.
Zenker’s diverticulum is a diverticulum of the mucosa of the pharynx above the cricopharyngeal muscle, which often causes clinical symptoms includingdysphagia, regurgitation, cough, and halitosis [1]. Endoscopic therapy is based on cutting the septum between the diverticulum and the esophageal lumen. Avariety of endoscopic methods have been used for this procedure, including laser, stapler, har...
متن کاملEndoscopic treatment of Zenker's diverticulum using a stag beetle knife.
Zenker’s diverticulum can be treated successfully using flexible endoscopy [1]. Several methods have been used to cut the septum of the diverticulum, such as LigaSure (Medtronic, Minneapolis, Minnesota, USA), needle-knife, and other submucosal dissection devices. Recently, isolated cases using the stag beetle (SB) knife dissector, SB jr 3.5mm, have been reported [2–4]. We present the case of a ...
متن کاملEndoscopic submucosal dissection using a novel irrigation hood-knife.
Endoscopic submucosal dissection tech− niques using an insulated−tip knife (IT knife) were introduced several years ago to allow en−bloc resection of early gastric cancers, since histological evaluations are essential in order to assess the risk of lymph−node metastasis [1, 2]. However, the technique requires special skills and involves a prolonged procedural time. We have therefore developed a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Endoscopy
سال: 2018
ISSN: 0013-726X,1438-8812
DOI: 10.1055/a-0601-6467