Endoneural selective stimulating using wire-microelectrode arrays
نویسندگان
چکیده
منابع مشابه
Endoneural selective stimulating using wire-microelectrode arrays.
In acute experiments eight 5- to 24-wire-microelectrode arrays were inserted into the common peroneal nerve of the rat, to investigate whether the electrodes could selectively stimulate motor units of the extensor digitorum longus (EDL) muscle. Twitch-force-recruitment curves were measured from the EDL for each array electrode. The curves were plotted on a double-logarithmic scale and parameter...
متن کاملIntraneural Stimulation using Wire-Microelectrode Arrays: Analysis of Force Steps in Recruitment Curves
In acute experiments on six Wistar rats, a wiremicroelectrode array was inserted into the common peroneal nerve. A 5-channel array and a 24-channel array were available. Each electrode in the array was used to generate a twitch contraction force recruitment curve for the extensor digitorum Longus muscle. We constructed a histogram of the pooled force steps in all recruitment curves. From a comp...
متن کاملMicroelectrode Arrays
The development of implantable devices which enable fully wireless transmission of brain signals, recorded by microelectrode arrays (MEA) as dynamical neural circuit information, is one important goal for advancing human neuroprostheses. Current brain sensing research for prostheses via first clinical trials is offering tantalizing glimpses for the future, even if these technologies are cumbers...
متن کاملLong-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex.
This paper describes a detailed protocol for obtaining chronic, multi-site unit recordings in cerebral cortex of awake animals for periods of three months or more. The protocol includes details for making relatively simple and inexpensive implantable multichannel electrodes that consist of arrays of separate microwires. The results reported in this paper suggest that a viable implant will have ...
متن کاملDielectrophoretic Characterization of Colloidal Particles Using Angled Microelectrode Arrays
This paper will present a characterization of a microfluidic device with embedded angled microelectrode arrays for the continuous flow-through dielectrophoretic separation of particles. The operation of the device is demonstrated using samples of colloidal latex spheres, achieving 100% particle deflection with low operating voltage of 10V. This characterization is essential for dielectrophoreti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Rehabilitation Engineering
سال: 1999
ISSN: 1063-6528