Endogenous Antibody Interferences in Immunoassays

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interferences in Immunoassays

Interference in immunoassays is a serious but underestimated problem (Ismail et al, 2002a). Interference is defined as “the effect of a substance present in the sample that alters the correct value of the result, usually expressed as concentration or activity, for an analyte” (Kroll & Elin, 1994). Immunoassays are analytically sensitive and measurements can frequently performed without prior ex...

متن کامل

Human anti-animal antibody interferences in immunological assays.

PURPOSE The scope and significance of human anti-animal antibody interference in immunological assays is reviewed with an emphasis on human anti-animal immunoglobulins, particularly human anti-mouse antibodies (HAMAs). ISSUES Anti-animal antibodies (IgG, IgA, IgM, IgE class, anti-isotype, and anti-idiotype specificity) arise as a result of iatrogenic and noniatrogenic causes and include human...

متن کامل

Methods for eliminating interferences in digoxin immunoassays caused by digoxin-like factors.

Endogenous, circulating digoxin-like immunoreactive factors (DLIF) are known to cross react with many antisera used in digoxin assays, complicating the quantification of serum digoxin. We have explored ways to decrease or remove the interference from DLIF in such assays. Prolonging the assay incubation from 30 to 60 min decreased apparent digoxin concentrations (attributable to DLIF) by an aver...

متن کامل

Role of antibody valency in hapten-heterologous immunoassays.

We studied the effects of hapten heterology on immunoassays of triiodothyronine (T3), digoxin, and cortisol, in a format involving labeled monoclonal antibodies and immobilized, protein-conjugated ligands. Replacing the homologous conjugated ligands T3, digoxin, and cortisol with their respective analogs diiodothyronine, digitoxin, and corticosterone led in each case to a decrease in the midpoi...

متن کامل

False-positive interferences of common urine drug screen immunoassays: a review.

Urine drug screen (UDS) immunoassays are a quick and inexpensive method for determining the presence of drugs of abuse. Many cross-reactivities exist with other analytes, potentially causing a false-positive result in an initial drug screen. Knowledge of these potential interferents is important in determining a course of action for patient care. We present an inclusive review of analytes causi...