Endodontic techniques with Nickel Titanium instruments: analysis of quality and efficiency of instrumentation in primary molars

نویسندگان

چکیده

ABSTRACT Objective: The purpose of the present in vitro study was to evaluate efficiency three different instruments root canals artificial primary molars as well quality fillings. Methods: Sixty were divided into groups 20 teeth. Each group submitted a technique: Group 1 - conventional manual technique using Kerr files; 2 with nickel-titanium 3 NiTi rotary technique. filled calcium hydroxide paste. Aspects such homogeneity fillings, taper and flowability preparations considered comparatively assess instrumentations. non-parametric Kruskal-Wallis Mann-Whitney tests used compare preparation canal considering times them. Results: All techniques equally effective at shaping working time shorter instrument (p=0.000). In pairwise comparisons, compared steel files (p=0.000) Comparing techniques, (p=0.011). Moreover, less variability found when used. Conclusions: mechanized method led operating comparison is therefore preferable option for

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cyclic fatigue testing of nickel-titanium endodontic instruments.

Cyclic fatigue of nickel-titanium, engine-driven instruments was studied by determining the effect of canal curvature and operating speed on the breakage of Lightspeed instruments. A new method of canal curvature evaluation that addressed both angle and abruptness of curvature was introduced. Canal curvature was simulated by constructing six curved stainless-steel guide tubes with angles of cur...

متن کامل

Fracture resistance of electropolished rotary nickel-titanium endodontic instruments.

The purpose of this study was to investigate the effect of electropolishing on cyclic flexural fatigue and torsional strength of rotary nickel-titanium endodontic instruments. Electropolished and nonelectropolished ISO size 30 (0.04 taper) EndoWave (J Morita Corporation, Osaka, Japan), ProFile (Dentsply Maillefer, Ballaigues, Switzerland), and RaCe (FKG, La-Chaux De Fonds, Switzerland) instrume...

متن کامل

Effect of cryogenic treatment on nickel-titanium endodontic instruments.

AIM To investigate the effects of cryogenic treatment on nickel-titanium endodontic instruments. The null hypothesis was that cryogenic treatment would result in no changes in composition, microhardness or cutting efficiency of nickel-titanium instruments. METHODOLOGY Microhardness was measured on 30 nickel-titanium K-files (ISO size 25) using a Vicker's indenter. Elemental composition was me...

متن کامل

A cleaning protocol for rotary nickel-titanium endodontic instruments.

BACKGROUND The cleaning of endodontic and all dental instruments prior to sterilization is a prerequisite for their processing for re-use. This study aimed to develop a clinically practical cleaning protocol for rotary nickel-titanium (NiTi) endodontic files prior to sterilization. METHODS Cleaning experiments were conducted on six different types of files that had been used on human teeth. T...

متن کامل

Comparison of Cleaning Efficacy and Instrumentation Time of Reciproc and Mtwo Rotary Systems in Primary Molars

Background and Aim: Pulpectomy of primary teeth is commonly performed with hand files and instruments. However, it is a time consuming procedure. Compared to hand files, rotary instrumentation has more advantages. The purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous mo-lars using Reciproc and Mtwo rotary systems. Materials an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: RGO - Revista Gaúcha de Odontologia

سال: 2023

ISSN: ['0103-6971', '1981-8637']

DOI: https://doi.org/10.1590/1981-86372023001620220005