Endobronchial Malposition of Matthys Pleural Catheter: A Case Report

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endobronchial Malposition of Matthys Pleural Catheter: A Case Report

Background Matthys catheters (Matthys drainage A Set, Bösch Feinmechanik und Medizintechnik GmbH, Gottenheim, Germany) are thin catheters with an external diameter of 2.7 mm, which are often used in internal medicine to drain pleural effusions. After puncturing the pleural cavity with a hollow needle the Matthys catheter is advanced through it without resistance. Once the three-way tap on the c...

متن کامل

A Rare Central Venous Catheter Malposition: A Case Report

INTRODUCTION Central venous catheter placement is a routine procedure for the management of critically ill patients; however, it is important to ensure its proper placement. A central venous catheter malposition may cause various complications, some of which can be fatal. CASE PRESENTATION We report an unexpected malposition of a catheter in the left internal jugular vein, where it entered in...

متن کامل

a rare central venous catheter malposition: a case report

conclusions we think one of the influential factors for leading a guidewire and catheter into a nominated vein may be the left sided bevel of the needle at the time of internal jugular vein needle and catheter insertion. we were required to continue going towards the subclavian vein and accidentally turned into the left internal mammary vein. introduction central venous catheter placement is a ...

متن کامل

Central venous catheter malposition due to dialysis catheter: a case report

A 56-year-old man on maintenance hemodialysis was admitted to the intensive care unit with septic shock and coagulopathy. As there was a dialysis catheter in the right internal jugular vein, the left internal jugular vein was cannulated with a central venous catheter to initiate vasopressor therapy. A chest X-ray showed formation of a catheter loop inside the left brachiocephalic vein, probably...

متن کامل

Internal jugular catheter malposition in a patient with end stage renal disease: a case report.

A 30-year-old female with end-stage renal disease was a candidate for dual lumen catheter placement. After catheter insertion, O2 saturation measurement of the aspirated blood from the catheter was similar to that of arterial blood. They referred the patient to our hospital after 48 hours. Diagnostic procedures revealed that the tip of the catheter had entered the pleural cavity. Catheter remov...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Thoracic and Cardiovascular Surgeon Reports

سال: 2015

ISSN: 2194-7635,2194-7643

DOI: 10.1055/s-0035-1564691