Emerging Techniques for Dose Optimization in Abdominal CT
نویسندگان
چکیده
منابع مشابه
Optimization of Parameters in 16-slice CT-scan Protocols for Reduction of the Absorbed Dose
Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...
متن کاملCan low-dose abdominal CT replace abdominal plain film in evaluation of acute abdominal pain?
BACKGROUND Non-contrast computed tomography (NCT) has become an important diagnostic tool in acute abdominal pain, but the drawback is the increased radiation dose compared to abdominal plain film (APF). PURPOSE To evaluate whether NCT, including low-dose computed tomography (LDCT, using 50 mAs), provides more diagnostic information than APF in patients presenting with acute non-traumatic abd...
متن کاملSize specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT/CT
Objective(s): Size specific dose estimate (SSDE) is a new parameter that includes patient size factor in its calculation. Recent studies have produced mixed results on the utility of SSDE, especially when automatic exposure control (AEC) was used. The objective of the study was to find out if there is a relationship between patient size and each of the parameters, SSDE...
متن کاملcomparison of low dose and standard dose abdominal ct scan in body stuffers
results the study consisted of 40 patients (all men, with mean age of 33.38 ± 7.4 years). ct evaluation with standard dose were positive in 22 patients (55%). only 1 (2.5%) ct scan assigned as unacceptable by each radiologist in low-dose group. noise average of low-dose protocol, was approximately 7 times greater than standard dose group, while dlp and ed are 9.7 times smaller. in comparison wi...
متن کاملoptimization of parameters in 16-slice ct- scan protocols for reduction of the absorbed dose
introduction in computed tomography (ct) technology, an optimal radiation dose can be achieved via changing radiation parameters such as ma, pitch factor, rotation time and tube voltage (kvp) for diagnostic images. materials and methods in this study, the brain, abdomen, and thorax scaning was performed using toshiba 16-slice scannerand standard aapm and ctdi phantoms. aapm phantom was used for...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: RadioGraphics
سال: 2014
ISSN: 0271-5333,1527-1323
DOI: 10.1148/rg.341135038