Emergency Methods for Rhesus Group Determination
نویسندگان
چکیده
منابع مشابه
Emergency Methods for Rhesus Group Determination.
The most reliable method for Rhesus group determination is probably the standard tube method (Landsteiner and Wiener, 1941; Boorman, Dodd, and Mollison, 1942; Taylor, 1943). This technique has only one serious disadvantage: it may take as long as two hours to perform, although occasional high-avidity anti-D sera will give clearcut results in 30 minutes or even less. For emergency Rhesus typing ...
متن کاملislanding detection methods for microgrids
امروزه استفاده از منابع انرژی پراکنده کاربرد وسیعی یافته است . اگر چه این منابع بسیاری از مشکلات شبکه را حل می کنند اما زیاد شدن آنها مسائل فراوانی برای سیستم قدرت به همراه دارد . استفاده از میکروشبکه راه حلی است که علاوه بر استفاده از مزایای منابع انرژی پراکنده برخی از مشکلات ایجاد شده توسط آنها را نیز منتفی می کند . همچنین میکروشبکه ها کیفیت برق و قابلیت اطمینان تامین انرژی مشترکان را افزایش ...
15 صفحه اولdevelopment of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles
a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...
Determination of ABO Blood Group and Rhesus factor from Tooth Pulp
Teeth can survive for a long time even after soft and skeletal tissues have been destroyed. The use of blood group substance in an individual remains unchanged throughout his life. The presence of ABO blood grouping makes it possible to determine the blood group and thereby assist in identifying even a highly decomposed body. To determine the ABO blood grouping from socket blood & extracted tee...
متن کاملMethods for Structure Determination
ScRh3Bx(x=0.0-1.0) has been investigated recently as an ultrahard material. Crystal structure refinements and electron density analyses of this material were carried out by synchrotron X-ray powder diffraction. The powder diffraction data were collected using Multi-Detector System powder diffractometer at the BL-4B2 experimental station of the Photon Factory. The crystal structure refinements w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Clinical Pathology
سال: 1951
ISSN: 0021-9746
DOI: 10.1136/jcp.4.1.55