Embolic Protection Device Use in Renal Artery Stent Placement
نویسندگان
چکیده
منابع مشابه
Embolic protection and platelet inhibition during renal artery stenting.
BACKGROUND Preservation of renal function is an important objective of renal artery stent procedures. Although atheroembolization can cause renal dysfunction during renal stent procedures, whether adjunctive use of embolic protection devices or glycoprotein IIb/IIIa inhibitors improves renal function is unknown. METHODS AND RESULTS One hundred patients undergoing renal artery stenting at 7 ce...
متن کاملCarotid artery stent placement with distal balloon protection: technical considerations.
BACKGROUND AND PURPOSE Most neurologic events that complicate the carotid artery stent placement procedure are embolic. Strategies are being developed and evaluated for their ability to minimize the clinical embolic risk. The purpose of this study was to determine the feasibility, safety, and technical considerations of performing carotid artery stent placement with use of a distal balloon anti...
متن کاملEmbolic Protection in Femoropopliteal Artery Intervention
F emoropopliteal occlusive disease is a major contributor to claudication and critical limb ischemia and is present in 20% to 40% of patients with peripheral arterial disease (PAD). As the population ages and technology advances, the number of endovascular treatments performed for femoropopliteal lesions is expected to increase. Endovascular recanalization and treatment of the superficial femor...
متن کاملManual external carotid artery manipulation for failed device advance through the stent in carotid artery stent placement. A technical note.
We report herein the usefulness of a manual external carotid artery manipulation for failed advancement of devices through the stent in carotid artery stent (CAS) placement with open cell type stent and filter type distal protection device. In all, 22 consecutive patients underwent CAS with filter type protection device between April 2008 and December 2009 in our institution, and failed advance...
متن کاملSafety of embolic protection device-assisted and unprotected intravascular ultrasound in evaluating carotid artery atherosclerotic lesions
BACKGROUND Significant atherosclerotic stenosis of internal carotid artery (ICA) origin is common (5-10% at ≥ 60 years). Intravascular ultrasound (IVUS) enables high-resolution (120 µm) plaque imaging, and IVUS-elucidated features of the coronary plaque were recently shown to be associated with its symptomatic rupture/thrombosis risk. Safety of the significant carotid plaque IVUS imaging in a l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Vascular and Interventional Radiology
سال: 2009
ISSN: 1051-0443
DOI: 10.1016/j.jvir.2009.01.025