Elution Column Preparation of Leaf Sample for Flame Photometry. I. Determination of Potassium in Tobacco
نویسندگان
چکیده
منابع مشابه
application and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples
ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...
15 صفحه اولSimultaneous Determination of Sodium and Potassium in Small Volumes of Fluid by Flame Photometry
INTRODUCTION In two earlier papers (Ramsay, 1950; Ramsay, Falloon & Machin, 1951) a method was described by which it was possible to determine the concentration of sodium in samples of fluid of the order of io~ cu.mm. in volume. This method has now been extended to include the determination of potassium simultaneously upon the same sample. It is still in the experimental stage of development; w...
متن کاملContinuous-recording flame photometry of sodium and potassium in serum.
Serum sodium and potassium analyses by continuous-flow flame photometry is a well-accepted procedure (1, 2). Recently Habig and Williamson (3) have used the widely available Instrumentation Laboratory Model 143 (IL-143) flame photometer for continuousflow analyses. Pennacchia et al. (4) have operated this flame photometer at rates as high as 120 samples per hour. In both systems the results app...
متن کاملSemimicro flame photometry of serum sodium and potassium.
BE PIONEER WORK of Lundegardh (1) established flame photometry as an analytical technic, but widespread interest was not aroused until 1945, when Barnes et al. (2) described a simple instrument which was much faster and at least as accurate as existing chemical methods for the determination of certain metals. A dormant clinical interest in the measurement of serum sodium and potassium was there...
متن کاملThe determination of magnesium in biological materials by flame photometry.
A method is described for the measurement of magnesium in biological materials and has been applied to the Unicam flame spectrophotometer SP 900. Samples were diluted in 10 mM strontium ethylenedinitrolo tetraacetate (EDTASr), 10 mM potassium carbonate, giving final magnesium concentrations of about 0.1 to 0.2 mM. The EDTASr almost eliminated the depression of magnesium emission by interfering ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of AOAC INTERNATIONAL
سال: 1961
ISSN: 0095-9111
DOI: 10.1093/jaoac/44.2.360