Elimination of the Inrush Current Phenomenon Associated with Single-Phase Offline UPS Systems
نویسندگان
چکیده
منابع مشابه
A New Pulsating Power Elimination Method for Single-Phase PWM AC/DC Converters with Minimum Voltage and Current Stress
An inherent problem of single-phase rectifiers is the existence of a pulsating portion in the input power, which pulsates at twice the grid frequency. If this pulsating power is transferred to the DC-link, it causes a significant amount of second-order harmonic at the output voltage. Since in many applications, such a high level of DC oscillation is not acceptable, so the pulsating power must b...
متن کاملA Method for Calculation of the Inrush Current in Single Phase Transformer including the Residual Flux
A field-circuit method for simulation of transients in a single-phase, two-winding transformer has been given. The magnetic field excited by the winding currents has been analyzed, and integral parameters have been determined. Including the equivalent circuit parameters and the magnetic residual flux in the silicon steel core, the developed method has been implemented for the transitional state...
متن کاملVolt-second Balance Method for Mitigation of Inrush Current in Single Phase Transformers
During the transient period at the start of transformer energization, it experiences a flux linkage that is up to twice its nominal steady state value and saturates the core. This causes a large inrush current to flow which affects the power system stability and power quality especially when the source is weak. Sequential phase energization technique and addition of neutral resistor are the maj...
متن کاملLeakage Current Elimination in Single Phase Transformer less Grid Connected Power Systems
Eliminating the leakage current is one of most important issues for transformer less inverters in grid connected photovoltaic applications. The technical challenge is how to keep the common mode voltage constant to reduce the leakage current. For this purpose an improved single phase transformer less inverter is proposed. It has two additional switches connected in the dc side. The PWM pulses f...
متن کاملA New Approach for Reactive Power Control of Single Phase Transformerless Inverter to Modify Power Quality in Stand Alone Micro-Grids with Current Leakage Elimination
Nowadays there has been an increasing interest in transformerless inverter for grid-connected photovoltaic (PV) system due to low cost, high efficiency and light weight. One of the reasons describe the grid behavior is capability of reactive power control by inverter. According to the standard VDE-AR-N 4105, grid-tied PV inverter of power rating below 3.68KVA, should attain power factor (PF) fr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2016
ISSN: 1996-1073
DOI: 10.3390/en9020096