Elimination of additive interference effects by H-point calibration curve method
نویسندگان
چکیده
منابع مشابه
EMF [ mV ] t EMF [ mV ] t CALIBRATION CURVE FOR CATION I CATION INTERFERENCE CALIBRATION CURVE
Among the techniques of detection used in clinical chemistry, optical and electrochemical methods are especially attractive. However, except for glass electrodes for pH measurement, potentiometric electrochemical sensors (ionselective electrodes) gained general acceptance in clinical analyzers and in clinical instrumentation, respectively, only around 1970 (for reviews see 1-5). Here we report ...
متن کاملElimination of interference information by a new hybrid algorithm for quantitative calibration of near infrared spectra.
A new hybrid algorithm is proposed to eliminate the interference information for multivariate calibration of near-infrared (NIR) spectra that includes noise, background and systemic spectral variation irrelevant to concentration. The method consists of two parts: approximate derivative based on continuous wavelet transform (CWT) and orthogonal signal correction (OSC). After the approximate deri...
متن کاملCapacity Bounds and High-SNR Capacity of the Additive Exponential Noise Channel With Additive Exponential Interference
Communication in the presence of a priori known interference at the encoder has gained great interest because of its many practical applications. In this paper, additive exponential noise channel with additive exponential interference (AENC-AEI) known non-causally at the transmitter is introduced as a new variant of such communication scenarios. First, it is shown that the additive Gaussian ch...
متن کاملSpectrophotometric study of complexation equilibria with H-point standard addition and H-point curve isolation methods.
The use of H-point curve isolation (HPCIM) and H-point standard addition methods (HPSAM) for spectrophotometric studies of complex formation equilibria are proposed. One step complex formation, two successive stepwise and mononuclear complex formation systems, and competitive complexation systems are studied successfully by the proposed methods. HPCIM is used for extracting the spectrum of comp...
متن کاملSimultaneous Spectrophotometric Determination of Vanadium(V) and Iron(III) in Micellar Medium by H-Point Standard Addition Method
H-Point Standard Addition Method (HPSAM) was applied for the simultaneous determination of V(V) and Fe(III). The method is based on the complex formation of V(V) and Fe(III) with chromazurol S (CAS) in acidic media and in the presence of cetyltrimethylammonium bromide (CTAB) as a micellizing agent. Acidic media and the presence of a micellar system improve selectivity and sensitivity. Fe (I...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Monatshefte für Chemie - Chemical Monthly
سال: 2019
ISSN: 0026-9247,1434-4475
DOI: 10.1007/s00706-019-2362-8