Elemental mapping of Portuguese ceramic pieces with a full-field XRF scanner based on a 2D-THCOBRA detector
نویسندگان
چکیده
In this work, we present a novel application of the full-field energy-dispersive X-ray fluorescence (EDXRF) imaging system based on MicroPattern Gaseous Detector (2D-THCOBRA) in cultural heritage field. The detector has an intrinsic capability with spatial resolution $$400\,{\upmu }\mathrm { m}\ \mathrm {FWHM}$$ , and is energy sensitive, presenting approximately $$1\ {keV\ FWHM}$$ at $$5.9\ {keV}$$ . XRF scanner 2D-THCOBRA allows mapping distribution elements large area samples high detection efficiency ( $$75\%$$ ), being very promising choice for elemental analysis samples. have demonstrated capabilities used it to assess restoration Portuguese faience piece.
منابع مشابه
X-ray imaging detector based on a position sensitive THCOBRA with resistive line
A new X-ray imaging detector based on a 2D-THCOBRA micropatterned structure using a simple position readout is proposed. It consists of a hybrid device that combines the properties of a THGEM and a 2D-MHSP in a single structure, having two charge multiplication stages reaching the demanded gains for the use of charge division readout methods. For position determination, the new 10×10 cm2 2D-THC...
متن کاملTime-Resolved μ-XRF and Elemental Mapping of Biological Materials
K. Tsuji, K. Tsutsumimoto, K. Nakano, K. Tanaka, A. Okhrimovskyy, Y. Konishi, and X. Ding Department of Applied Chemistry; Graduate School of Engineering; Osaka City University; 3-3-138 Sugimoto; Sumiyoshi-ku, Osaka 558-8585; Japan Telephone/Fax: +81-(0)6-6605-3080; E-mail: [email protected] 2) JST-PREST; 4-1-8 Honcho Kawaguchi, Saitama; Japan Institute of Low Energy Nuclear Physi...
متن کاملProstate Helical Tomotherapy: A semi-empirical estimation of the scaling factor based on 2D approximating field
Background: In Helical Tomotherapy (HT), the scaling factor (SF) is the time in seconds that each leaf viewing a target would need to be open to deliver the prescribed dose. The SF is patient-specific and is used to calculate the rotational period of the gantry, and the total treatment time (TTT) of the HT. The SF is generally difficult to estimate. Currently, it takes about one hour t...
متن کاملconstruction and validation of a computerized adaptive translation test (a receptive based study)
آزمون انطباقی رایانه ای (cat) روشی نوین برای سنجش سطح علمی دانش آموزان می باشد. در حقیقت آزمون های رایانه ای با سرعت بالایی به سمت و سوی جایگزین عملی برای آزمون های کاغذی می روند (کینگزبری، هاوسر، 1993). مقاله حاضر به دنبال آزمون انطباقی رایانه ای برای ترجمه می باشد. بدین منظور دو پرسشنامه مشتمل بر 55 تست ترجمه میان 102 آزمودنی و 10 مدرس زبان انگلیسی پخش گردید. پرسشنامه اول میان 102 دانشجوی س...
Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: European Physical Journal Plus
سال: 2021
ISSN: ['2190-5444']
DOI: https://doi.org/10.1140/epjp/s13360-021-01422-y