Electrothermal atomic absorption spectrometric determination of germanium by coprecipitation with hafnium hydroxide.
نویسندگان
چکیده
منابع مشابه
Preconcentration of gallium by coprecipitation with synthetic zeolites prior to determination by electrothermal atomic absorption spectrometry.
Synthetic zeolites were dissolved in nitric acid, and the resulting solution used as a coprecipitant for the preconcentration of trace amounts of gallium in water samples prior to determination by electrothermal atomic absorption spectrometry (ETAAS). The gallium preconcentration conditions and the ETAAS measurement conditions were optimized. Gallium was quantitatively concentrated with the zeo...
متن کاملCoprecipitation of trace metal ions in water with bismuth(III) diethyldithiocarbamate for an electrothermal atomic absorption spectrometric determination.
متن کامل
Determination of Aluminum in Dialysis Concentrates by Atomic Absorption Spectrometry after Coprecipitation with Lanthanum Phosphate
This method was developed for the determination of trace amounts of aluminum(III) in dialysis concentrates using atomic absorption spectrometry after coprecipitation with lanthanum phosfate. The analytical parameters that influenced the quantitave coprecipitation of analyte including amount of lanthanum, amount of phosfate, pH and duration time were optimized. The % recoveries of the analyte io...
متن کاملDetermination of Aluminum in Dialysis Concentrates by Atomic Absorption Spectrometry after Coprecipitation with Lanthanum Phosphate
This method was developed for the determination of trace amounts of aluminum(III) in dialysis concentrates using atomic absorption spectrometry after coprecipitation with lanthanum phosfate. The analytical parameters that influenced the quantitave coprecipitation of analyte including amount of lanthanum, amount of phosfate, pH and duration time were optimized. The % recoveries of the analyte io...
متن کاملElectrothermal atomic absorption spectrometric determination of aluminum in serum with a new technique for protein precipitation.
We have studied the electrothermal atomic absorption measurement of aluminum in serum samples by direct analysis with standard additions and the use of a matrix modifier. We have also measured aluminum by analysis of the supernate after pretreatment of serum with concentrated nitric acid to precipitate proteins, and have compared the results obtained by these two techniques. Both appear to elim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 1989
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.5.181