Electronically Compensated Voltage Transformer with Capacitive Reference
نویسندگان
چکیده
منابع مشابه
Measurement Error Estimation for Capacitive Voltage Transformer by Insulation Parameters
Measurement errors of a capacitive voltage transformer (CVT) are relevant to its equivalent parameters for which its capacitive divider contributes the most. In daily operation, dielectric aging, moisture, dielectric breakdown, etc., it will exert mixing effects on a capacitive divider’s insulation characteristics, leading to fluctuation in equivalent parameters which result in the measurement ...
متن کاملA picopower temperature-compensated, subthreshold CMOS voltage reference
A voltage reference consisting of only two nMOS transistors with different threshold voltages is presented. Measurements performed on 23 samples from a single batch show a mean reference voltage of 275.4mV. The subthreshold conduction and the low number of transistors enable to achieve a mean power consumption of only 40 pW. The minimum supply voltage is 0.45 V, which coincides with the lowest ...
متن کاملVoltage Mode Electronically Tunable Full-wave Rectifier
The paper presents a new realization of bipolar full-wave rectifier of input sinusoidal signals, employing one MO-CCCII (multiple output current controlled current conveyor), a zero-crossing detector (ZCD), and one resistor connected to a fixed potential. The circuit provides the operating frequency up to 10 MHz with increased linearity and precision in processing of low-level input voltage sig...
متن کاملA high-voltage pulse transformer with a modular ferrite core.
A high ratio (winding ratio of 1:80) pulse transformer with a modular ferrite core was developed for a repetitive resonant charging system. The magnetic core is constructed from 68 small blocks of ferrites, glued together by epoxy resin. This allows a high degree of freedom in choosing core shape and size. Critical issues related to this modular design are the size tolerance of the individual f...
متن کاملTransformer voltage control and Tap changing
The voltage control is performed by changing the turns ratio. This is done by provision of taps in the winding. The volts per turn available in large transformers is quite high and hence a change of even one turn on the LV side represents a large percentage change in the voltage. Also the LV currents are normally too large to take out the tapping from the windings. LV winding being the inner wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Power and Energy
سال: 2007
ISSN: 0385-4213,1348-8147
DOI: 10.1541/ieejpes.127.953