Electronic Ballast Design for UV Lamps based on UV Dose, applied to Drinking Water Purifier.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endotoxin inactivation in water by using medium-pressure UV lamps.

Deionized water was spiked with various concentrations of endotoxin and exposed to UV irradiation from medium-pressure UV lamps to assess endotoxin inactivation. It was found that endotoxin inactivation was proportional to the UV dose under the conditions examined. The inactivation rate was determined to be approximately 0.55 endotoxin unit/ml per mJ/cm(2) of irradiation delivered.

متن کامل

Enhanced UV inactivation of adenoviruses under polychromatic UV lamps.

Adenovirus is recognized as the most UV-resistant waterborne pathogen of concern to public health microbiologists. The U.S. EPA has stipulated that a UV fluence (dose) of 186 mJ cm(-2) is required for 4-log inactivation credit in water treatment. However, all adenovirus inactivation data to date published in the peer-reviewed literature have been based on UV disinfection experiments using UV ir...

متن کامل

Calculating UV Dose for UV/AOP Reactors Using Dose/Log as a Water-Quality Metric

A method for scale up of UV/AOP reactors is outlined that uses bench scale testing to determine the UV dose required per log destruction (DL) of a particular contaminant. This can then be used in CFD Modeling to size a full-scale UV reactor and to test the reactor in performance trials. Methods for calculating dose based on the path length distribution in a UV reactor are given.

متن کامل

The Effect of UV and Combined Chlorine/UV Treatment on Coliphages in Drinking Water Disinfection

Ultraviolet (UV) irradiation is a common way to disinfect drinking water, but some viruses are very resistant to UV. Drinking water was disinfected with UV after spiking with MS2 and 18 different coliphages isolated from municipal wastewater effluent. In addition, some coliphages were disinfected with combined treatment of chlorine/UV or vice versa with UV/chlorine. A UV-dose of 22 mWs/cm2 caus...

متن کامل

Impacts of goethite particles on UV disinfection of drinking water.

A unique association between bacterial cells and small goethite particles (approximately 0.2 by 2 microm) protected Escherichia coli and Pseudomonas putida from UV inactivation. The protection increased with the particle concentration in the turbidity range of 1 to 50 nephelometric turbidity units and with the bacterium-particle attachment time prior to UV irradiation. The lower degree of bacte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Industrial Electronics

سال: 2016

ISSN: 0278-0046,1557-9948

DOI: 10.1109/tie.2016.2549500