Electron Tomographic Comparison of Frozen-Hydrated and Freeze-Substituted Sections of High-Pressure Frozen Rat-Liver Tissue

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electron microscopy of frozen hydrated biological specimens.

The use of frozen hydrated specimens for molecular structure determination is limited primarily by radiation damage. The radiation damage effect in frozen hydrated catalase crystals has been measured in terms of the loss of electron diffraction. The results show an improvement for this type or:specimen relative to wet hydrated or to glucose embedded catalase crystals at room temperature. Bright...

متن کامل

Accuracy of Frozen Sections

Background and Objective: Intraoperative consultation by frozen section is a high – risk procedure with important consequences. Therefore, it is critical to determine efficiency of frozen section performance periodically. This study was performed to determine the accuracy of frozen section in Urmia University of Medical Sciences. Materials & Methods:Inthis cross sectional study, we compared th...

متن کامل

Frozen Thin Sections of Fresh Tissue for Electron Microscopy, with a Description of Pancreas and Liver

A simple method has been developed that allows frozen thin sections of fresh-frozen tissue to be cut on a virtually unmodified ultramicrotome kept at room temperature. A bowl-shaped Dewar flask with a knifeholder in its depths replaces the stage of the microtome; a bar extends down into the bowl from the microtome's cutting arm and bears the frozen tissue near its lower end. When the microtome ...

متن کامل

Cryo-transmission electron microscopy of frozen-hydrated sections of Escherichia coli and Pseudomonas aeruginosa.

High-pressure freezing of Escherichia coli K-12 and Pseudomonas aeruginosa PAO1 in the presence of cryoprotectants provided consistent vitrification of cells so that frozen-hydrated sections could be cut, providing approximately 2-nm resolution of structure. The size and shape of the bacteria, as well as their surface and cytoplasmic constituents, were nicely preserved and compared well with ot...

متن کامل

Electron microscopy of ultrathin frozen sections of pollen grains.

Electron Microscopy of Ultrathin Frozen Sections of Pollen Grains: H. Ferndndez-Moran and A. Ortile Dahl 465 George Walter McCoy: 1876-1952: Charles Armstrong 468 'News and Notes Royal Society of 'Canada: B. W. Sargent 469 Technical Papers Studies on Natural Pollination of Hevea brasiliensis in Brazil: H. E. Warmke _ 474 The Rate of Endogenous Respiration as Affected by the Oxidation of Exogeno...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Microscopy and Microanalysis

سال: 2003

ISSN: 1431-9276,1435-8115

DOI: 10.1017/s1431927603445893