Electron microscopy of negatively stained and unstained fibrinogen.
نویسندگان
چکیده
منابع مشابه
Electron microscopy of negatively stained and unstained fibrinogen.
Electron microscope images of negatively stained fibrinogen are predominantly asymmetric rods 450 A in length and about 60 A in width. The molecules appear to have considerable flexibility, and mass distribution along the major axis is not uniquely distinguished despite apparent beading in some particles. Scanning transmission electron microscopy of unstained fibrinogen again demonstrates that ...
متن کاملElectron Microscopy of Metal-shadowed and Negatively Stained Microtubule Protein
Microtubule protein purified from porcine brain was fixed at low protein concentration with glutaraldehyde under conditions which maximize the relative concentration of the ring-shaped 30 S oligomer. Fixed oligomer was separated from glutaraldehyde and other protein species by column chromatography. The fixed, isolated oligomer was deposited on electron microscopy grids, dehydrated, and then cr...
متن کاملElectron microscopy of metal-shadowed and negatively stained microtubule protein. Structure of the 30 S oligomer.
Microtubule protein purified from porcine brain was fixed at low protein concentration with glutaraldehyde under conditions which maximize the relative concentration of the ring-shaped 30 S oligomer. Fixed oligomer was separated from glutaraldehyde and other protein species by column chromatography. The fixed, isolated oligomer was deposited on electron microscopy grids, dehydrated, and then cr...
متن کاملElectron microscopy of fibrinogen and fibrin.
It has been demonstrated through electron microscopy and x-ray diffraction that there are present, in certain protein fibrils, structural periodicities having dimensions up to several hundred angstrom units. Examples are collagen (l-3), paramyosin (4,5), the trichocysts of Paramecium (6, 7), and fibrin (8). The application of phosphotungstic acid (4) and other heavy metal compounds greatly enha...
متن کاملThe interpretation of electron micrographs of negatively stained native collagen.
Deamination of native rat tail collagen followed by treatment with 1,2-cyclohexanedione removes the positive charge from the side chains of the lysine and hydroxylysine residues and blocks approximately 7 0 % of the positively charged side chains of the arginine residues. When such specimens are examined in the electron microscope after negative staining with 2 % potassium phosphotungstate at p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Proceedings of the National Academy of Sciences
سال: 1980
ISSN: 0027-8424,1091-6490
DOI: 10.1073/pnas.77.6.3139