Electron Differential Phase Microscopy with an A-B Effect Phase Plate

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transmission electron microscopy with Zernike phase plate.

The possibility of implementing a Zernike phase plate in a transmission electron microscope is investigated both theoretically and experimentally. The phase-retarding plate in the form of thin film with a hole in the center is positioned in the back-focal plane of the objective lens. The experiments show that the phase plate functions as predicted, producing a cosine-type phase contrast transfe...

متن کامل

Object wave reconstruction by phase-plate transmission electron microscopy.

A method is described for the reconstruction of the amplitude and phase of the object exit wave function by phase-plate transmission electron microscopy. The proposed method can be considered as in-line holography and requires three images, taken with different phase shifts between undiffracted and diffracted electrons induced by a suitable phase-shifting device. The proposed method is applicab...

متن کامل

A nanocrystalline Hilbert phase-plate for phase-contrast transmission electron microscopy.

Thin-film-based phase-plates are applied to enhance the contrast of weak-phase objects in transmission electron microscopy. In this work, metal-film-based phase-plates are considered to reduce contamination and electrostatic charging, which up to now limit the application of phase-plates fabricated from amorphous C-films. Their crystalline structure requires a model for the simulation of the ef...

متن کامل

Volta potential phase plate for in-focus phase contrast transmission electron microscopy.

We describe a phase plate for transmission electron microscopy taking advantage of a hitherto-unknown phenomenon, namely a beam-induced Volta potential on the surface of a continuous thin film. The Volta potential is negative, indicating that it is not caused by beam-induced electrostatic charging. The film must be heated to ∼ 200 °C to prevent contamination and enable the Volta potential effec...

متن کامل

Effect of a physical phase plate on contrast transfer in an aberration-corrected transmission electron microscope.

In this theoretical study we analyze contrast transfer of weak-phase objects in a transmission electron microscope, which is equipped with an aberration corrector (C(s)-corrector) in the imaging lens system and a physical phase plate in the back focal plane of the objective lens. For a phase shift of pi/2 between scattered and unscattered electrons induced by a physical phase plate, the sine-ty...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Microscopy and Microanalysis

سال: 2015

ISSN: 1431-9276,1435-8115

DOI: 10.1017/s1431927615010508