Electron backscattered diffraction using a new monolithic direct detector: High resolution and fast acquisition
نویسندگان
چکیده
A monolithic active pixel sensor based direct detector that is optimized for the primary beam energies in scanning electron microscopes implemented back-scattered diffraction (EBSD) applications. The high detection efficiency of and its large array pixels allow sensitive accurate Kikuchi bands arising from excitation 4 keV to 28 keV, with optimal contrast occurring range 8–16 keV. pattern acquisition speed substantially improved via a sparse sampling mode, resulting reduced number on detector. Standard inpainting algorithms are effectively estimate information skipped regions acquired pattern. For EBSD mapping, an as 5988 scan points per second demonstrated, tolerable fraction indexed accuracy. collective capabilities spanning angular resolution patterns achieved same detector, facilitating simultaneous modalities enable multitude advanced applications, including lattice strain structural refinement, low-dose characterization, 3D-EBSD dynamic situ EBSD.
منابع مشابه
Electron energy loss and diffraction of backscattered electrons from silicon
Electrons backscattered from crystals can show Kikuchi patterns: variations in intensity for different outgoing directions due to diffraction by the lattice. Here, we measure these effects as a function of their energy loss for 30 keV electrons backscattered from silicon. The change in diffraction contrast with energy loss depends strongly on the scattering geometry. At steep incidence on the s...
متن کاملFast Direct GPS Signal Acquisition Using FPGA
∗ School of Electrical Engineering and Computer Science, Ohio University, Athens, OH 45701, email: [email protected], [email protected], tel: (740)593-1580, fax: (740)593-0007. Abstract − This paper presents a novel P-code generator design strategy and direct GPS P-code acquisition technique. This method not only helps software simulation and simplifies FPGA hardware desi...
متن کاملA Fast, Robust, Automatic Blink Detector
Introduction “Blink” is defined as closing and opening of the eyes in a small duration of time. In this study, we aimed to introduce a fast, robust, vision-based approach for blink detection. Materials and Methods This approach consists of two steps. In the first step, the subject’s face is localized every second and with the first blink, the system detects the eye’s location and creates an ope...
متن کاملThe collection of high-resolution electron diffraction data.
A number of atomic-resolution structures of membrane proteins (better than 3Å resolution) have been determined recently by electron crystallography. While this technique was established more than 40 years ago, it is still in its infancy with regard to the two-dimensional (2D) crystallization, data collection, data analysis, and protein structure determination. In terms of data collection, elect...
متن کاملDomino phase-retrieval algorithm for structure determination using electron diffraction and high-resolution transmission electron microscopy patterns.
Direct-method formalism to determine atomic structures using electron diffraction data is here aimed at a general solution of the phase-retrieval problem, consequently combining electron diffraction (ED) and high-resolution transmission electron microscopy (HRTEM) patterns in a 'domino' fashion. While there are similarities to conventional (kinematical) direct methods, there remain major differ...