Electromagnetic Characteristics of Detection for Grounding Grid

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of dosimetric characteristics of a grid block fabricated for Mega-voltage grid therapy purposes

Background: In conventional radiation therapy, regarding normal tissue tolerance, the treatment of bulk tumors is one of the remaining challenges. Grid Radiation Therapy (GRT) is a technique to deliver high doses, approximately 15 – 20 Gy per fraction, to several small volumes located in a large radiation field. This can be performed using a grid block. The current work has concentrate...

متن کامل

islanding detection methods for microgrids

امروزه استفاده از منابع انرژی پراکنده کاربرد وسیعی یافته است . اگر چه این منابع بسیاری از مشکلات شبکه را حل می کنند اما زیاد شدن آنها مسائل فراوانی برای سیستم قدرت به همراه دارد . استفاده از میکروشبکه راه حلی است که علاوه بر استفاده از مزایای منابع انرژی پراکنده برخی از مشکلات ایجاد شده توسط آنها را نیز منتفی می کند . همچنین میکروشبکه ها کیفیت برق و قابلیت اطمینان تامین انرژی مشترکان را افزایش ...

15 صفحه اول

A New Method of Grounding Grid Design

In order to equalize the electric potential distribution of the grounding grid surface, and improve the safety level of the grounding grid, method for optimal arrangement of conducts in the grounding grid is proposed in this paper. The calculation results about maximum touch voltages and mesh potentials show that the method can reduce touch voltage and equilibrium surface potential. It is shown...

متن کامل

Signal transmission model for the substations grounding grid

The signal of the wireless sensor network in Grounding grid, owing to energy loss, network congestion, path constraints and other factors, is easy to delay even partially losing. In order to ensure that the signal can be transmitted effectively in grounding grids for the substation, this paper presents a method based on traffic model of back-off balanced multiple sensor network cooperation mode...

متن کامل

evaluation of dosimetric characteristics of a grid block fabricated for mega-voltage grid therapy purposes

background: in conventional radiation therapy, regarding normal tissue tolerance, the treatment of bulk tumors is one of the remaining challenges. grid radiation therapy (grt) is a technique to deliver high doses, approximately 15 – 20 gy per fraction, to several small volumes located in a large radiation field. this can be performed using a grid block. the current work has concentrated on the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: DEStech Transactions on Engineering and Technology Research

سال: 2017

ISSN: 2475-885X

DOI: 10.12783/dtetr/iceea2016/6638