Electrode positions, transformation coordinates for ECG reconstruction from S-ICD vectors
نویسندگان
چکیده
منابع مشابه
Electrode positions, transformation coordinates for ECG reconstruction from S-ICD vectors
The article contains data pertaining to the reconstruction of an 8-lead ECG from 2 subcutaneous implantable cardioverter defibrillator vectors. The location of electrodes on the precordium required for the data collection are detailed; the flow chart for patient selection and exclusion is shown; the summary data of the root mean square error (RMSE) (in microvolts) and Pearson r for the ECG tran...
متن کاملOptimization of the Electrode Positions of Multichannel ECG for the Reconstruction of Ischemic Areas by Solving the Inverse Electrocardiographic Problem
Myocardial ischemia is one of the leading causes of morbidity and mortality in the western countries. It is of importance to efficiently and accurately detect and localize ischemia in the early stage. The solution of the inverse problem of electrocardiography provides a promising noninvasive approach for the localization of ischemic areas. However, the general electrode configuration of multich...
متن کاملEcg-electrode Induced Hypopigmentation.
Skin reactions following the application of electrocardiography (ECG) electrodes have been reported in adults and children, and are postulated to result from contact with the conductive gel or adhesive used on the electrodes. Although contact dermatitis is the usual cause of such reactions, contact depigmentation or hypopigmentation may also occur. We report a case of hypopigmentation in a heal...
متن کاملDetermination of optimal electrode positions for tDCS
The present study introduces a new approach to determining optimal electrode positions in transcranial direct current stimulation (tDCS). Electric field and 3D conduction current density were analyzed using 3D finite element method (FEM) formulated for a dc conduction problem. The electrode positions for minimal current injection were optimized by changing the Cartesian coordinate system into t...
متن کاملA Novel Electrode for Pasteless Ecg Monitoring
A dry bracelet electrode for electrocardiographic (ECG) signal monitoring was developed and successfully tested in human volunteers. The new electrode dispenses with the usual gel application and the previous skin preparation to monitor the signal. It was fabricated from a polyethylene tereftalate (PET) polymer sheet that was coated with a thin conductive titanium nitride (TiN) layer. As the di...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Data in Brief
سال: 2017
ISSN: 2352-3409
DOI: 10.1016/j.dib.2017.02.041